Data Sheet

Input Current
- At no load
24 Vin models:
8 mA typ.
48 Vin models:
6 mA typ.
110 Vin models:
5 mA typ.
Surge Voltage
24 Vin models:
50 VDC max. (1 s max.)
48 Vin models:
100 VDC max. (1 s max.)
110 Vin models:
170 VDC max. (1 s max.)
Input Inrush Current
15 A typ.
Under Voltage Lockout
24 Vin models:
7 VDC min. / 8 VDC typ. / 8.8 VDC max.
48 Vin models:
15 VDC min. / 16 VDC typ. / 17.5 VDC max.
110 Vin models:
37 VDC min. / 40 VDC typ. / 42 VDC max.
Recommended Input Fuse
24 Vin models:
4'000 mA (slow blow)
48 Vin models:
2'000 mA (slow blow)
110 Vin models:
1'000 mA (slow blow)
Reverse Voltage Protection
Parallel diode
Input Specifications
Voltage Set Accuracy
±1% max. (Single Output)
+1% / -1.2% (Dual Output)
Regulation
- Input Variation (Vmin - Vmax)
single output models:
0.5% max.
dual output models:
0.5% max.
- Load Variation (0 - 100%)
single output models:
1.5% max. (5 VDC models)
1% max. (other models)
dual output models:
1% max. (Output 1)
1% max. (Output 2)
- Cross Regulation
(25% / 100% asym. load)
dual output models:
5% max.
Ripple and Noise
(20 MHz Bandwidth)
- single output
5 Vout models:
75 mVp-p max.
12 Vout models:
100 mVp-p max.
15 Vout models:
100 mVp-p max.
24 Vout models:
150 mVp-p max.
- dual output
12 / -12 Vout models:
100 / 100 mVp-p max.
15 / -15 Vout models:
100 / 100 mVp-p max.
Capacitive Load
- single output
5 Vout models:
5'000 µF max.
12 Vout models:
850 µF max.
15 Vout models:
700 µF max.
24 Vout models:
250 µF max.
- dual output
12 / -12 Vout models:
500 / 500 µF max.
15 / -15 Vout models:
350 / 350 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Hold-up Time
10 ms min.
Start-up Time
100 ms typ.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
150% typ. of Iout max.
Overvoltage Protection
125% typ. of Vout nom.
Transient Response
- Response Time
250 µs typ. (25% Load Step)
Output Specifications
TEQ 20WIR Series, 20 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
August 5, 2019
Page 2 / 4