Data Sheet

THM 6 Series, 6 Watt
http://www.tracopower.com Page 2 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current no load 5 Vin models: 20 mA typ.
12 Vin models: 10 mA typ.
24 Vin models: 6 mA typ.
48 Vin models: 4 mA typ.
Surge voltage (3 sec. max.) 5 Vin models: 16 V max.
12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Start-up voltage 5 Vin models: 4.5 VDC (or lower)
12 Vin models: 9 VDC (or lower)
24 Vin models: 18 VDC (or lower)
48 Vin models: 36 VDC (or lower)
Startup time 30 ms
Under voltage shut down 5 Vin models: 4 VDC typ.
12 Vin models: 8 VDC typ.
24 Vin models: 16 VDC typ.
48 Vin models: 33 VDC typ.
Conducted noise EN55022 class A (internal filter)
EMC immunity – ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
– Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
– Fast transient / surge EN 61000-4-4, ±2 kV, perf. criteria A
(with external input capacitor / diode) EN 61000-4-5, ±2 kV perf. criteria A
5 Vin models: Nippon chemi-con KY 1000 µF/ 25 V and
reverse diode (Vishay V10P45) in parallel
12 & 24 Vin models: Nippon chemi-con KY 470 µF/ 50 V
48 Vin models: Nippon chemi-con KY 330 µF/ 100 V
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
– Magnetic field immunity EN 61000-4-8
100 A/m, continuous, perf. criteria A
1000 A/m, 1 sec., perf. criteria A
Output Specifications
Voltage set accuracy ±1 % max.
Regulation Input variation single output: 0.2 % max.
dual output: 0.5 % max.
– Load variation 0 – 100 % single output: 0.2 % max.
dual output: 1.0 % max.
– Cross regulation dual output: 5.0 % max. (asymmetrical load 25/100 %)
Minimum load not required
Ripple and noise (20 MHz Bandwidth) 3.3 & 5.0 VDC models: 30 mVp-p typ. with cap. 10 µF/25 V X7R MLCC
12 & 15 VDC models: 40 mVp-p typ. with cap. 10 µF/25 V X7R MLCC
24 VDC models: 50 mVp-p typ. with cap. 4.7 µF/50 V X7R MLCC
Transient response – Recovery time (25% load step change) 250 s typ.
Over load protection at 150 % typ. of Iout rated (hiccup mode)
Short circuit protection Continuous, automatic recovery
Over voltage protection –Single output 3.3 VDC models: 3.7 – 5.0 VDC
5.0 VDC models: 5.6 – 7.0 VDC
12 VDC models: 13.5 – 16.0 VDC
15 VDC models: 18.3 – 22.0 VDC
24 VDC models: 29.1 – 34.5 VDC
–Dual output ±5 VDC models: 5.6 – 7.0 VDC
±12 VDC models: 13.5 – 18.2 VDC
±15 VDC models: 17.0 – 22.0 VDC