Installation Instructions

Revised 08/01/2018 Copyright © 2018 Trade-Wind Manufacturing, LLC Proverbs 22:29 Page 8
PART 4 Electrical Connection
IMPORTANT: Copy this page for your electrical installer.
WARNING! Ensure that the power supply is disconnected before proceeding. Verify that the power supply
matches the ratings found on the appliance data label before proceeding. The complete appliance must be
properly grounded at all times when electrical power is applied. Do not ground the appliance with the neutral
(white) house supply wire. A separate ground wire must be utilized. Failure to complete electrical connections
properly may result in damaged or non-functional systems. Follow instructions carefully to ensure proper
installation.
It is the owner’s responsibility to ensure that a qualified person performs the electrical connection of this
appliance. The electrical installation, including minimum supply wire size, must comply with the National
Electric Code ANSI/NFPA 70-1990 (or latest revision) and local codes and ordinances. A copy of this
standard may be obtained from:
National Fire Protection Association, 1 Batterymarch Park, Quincy, Massachusetts 02169-7471
INSTRUCTIONS: A 15 to 20 amp electrical service is recommended for proper electrical supply. Always
observe local building codes. Always use a dedicated circuit.
Wire connections: (See Diagram Below) There are 3 wires on the front panel that require connection.
BLACK
120 VAC from electrical panel (usually black)
WHITE
Neutral from electrical panel (white)
GREEN
Ground from electrical panel (usually green)
CAUTION: The neutral wire (white) must only be connected to the white neutral wire coming in from the electrical panel.
Wiring Diagram
Diagram 1: All Models with Factory Installed Internal Motor/Blower
Liner
House Electrical
Panel
Green
120V Black
White
(N)