Stand-Alone Devices Installation Operation

12
SSDTF10xx-10x
Technical Specifications
For use with Transition Networks Model SSDTF10xx-10x or equivalent
Standards: Emissions: CISPR A; Telecordia TR-NWT-001089
(designed to meet; NOT tested); FCC Part 68; T1/E1
Physical layer: ITU-T, ANSI, AT&T, and ETSI; European
Technical Standard: TBR 12; British Technical
Publication: PD 7024 : 1994 (NTR 4)
Dimensions: 3.25" x 4.7" x 1" (83 mm x 119 mm x 25 mm)
Weight: 10 oz. (283 g) approximately
Power consumption: 3.7 Watts
Power supply: 12VDC, 0.8A (North America, Europe, UK)
12VDC, 1.25A (NZ, Australia, S Africa, JP, Latin Am)
(The external power supply provided with this product
is UL listed by the power supply’s manufacturer.)
MTBF: 47,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
116,000 hours (Bellcore7 V5.0)
Environment: 0°C to 50°C (32°F to 122° F )
Storage Temp: -15°C to 65°C (5°F to 149°F)
Humidity: 10 to 90%, non condensing
Altitude: 0 to 10,000 feet
Warranty: Lifetime
The information in this user’s guide is subject to change. For the most up-to-date
information on the SSDTF10xx-10x Device, view the user’s guide on-line at:
www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
CAUTION:
Visible and invisible laser radiation when open. Do not stare into the
beam or view directly with optical instruments.
CAUTION:
Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.
13
Troubleshooting
If the device fails, isolate and correct the failure by determining the answers to the
following questions and then taking the indicated action:
1. Is the PWR (Power) LED illuminated?
NO
Is the power adapter the proper type of voltage and cycle frequency for
the AC outlet? (See “Technical Specifications” on page 12.)
Is the power adapter properly installed in the device and in the outlet?
Does the grounded AC outlet provide power?
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 2.
2. Is the SDC (Signal Detect/Copper) LED illuminated?
NO
Check the twisted-pair copper cable for the proper connection.
Check the MDI/MDI-X switch for the correct twisted-pair copper cable
configuration (see page 3).
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 3.
3. Is the SDF (Signal Detect/Fiber) LED illuminated?
NO
Check the fiber cables for proper connection.
Verify that the TX and RX cables on the local device are connected to the
RX and TX ports, respectively, on the remote device.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 4.