Network Cables - Network Adapter User Manual

6
SSEFE10xx-10x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber Cable
Bit Error Rate: <10
-9
Single mode: 9 µm
SSEFE1012-100 1310 nm single mode
Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -32.0 dBm max: -5.0 dBm
Link Budget: 17.0 dB
SSEFE1014-100 1310 nm single mode
Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -32.0 dBm max: -5.0 dBm
Link Budget: 17.0 dB
SSEFE1015-100 1310 nm single mode
Fiber Optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm
Fiber Optic Receiver Sensitivity: min: -34.0 dBm max: -5.0 dBm
Link Budget: 26.0 dB
SSEFE1022-100 1310 nm single mode
Fiber Optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm
Fiber Optic Receiver Sensitivity: min: -34.0 dBm max: -5.0 dBm
Link Budget: 26.0 dB
SSEFE1029-100 1310 nm (TX)/1550 nm (RX) simplex
Fiber-optic Transmitter Power: min: -14.0 dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -33.0 dBm max: -3.0 dBm
Link Budget: 19.0 dB
SSEFE1029-101 1550 nm (TX)/1310 nm (RX) simplex
Fiber-optic Transmitter Power: min: -14.0 dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -33.0 dBm max: -3.0 dBm
Link Budget: 19.0 dB
The fiber optic transmitters on this device meet Class I Laser safety
requirements per IEC-825/CDRH standards and comply with 21
CFR1040.10 and 21CFR1040.11.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat
7
Cable Specifications -- Continued
Copper Cable
Category 3: (Minimum requirement for 10 Mb/s operation)
Gauge 24 to 22 AWG
Attenuation 11.5 dB/100m @ 5-10 MHz
Category 5: (Minimum requirement for 100 Mb/s operation)
Gauge 24 to 22 AWG
Attenuation 22.0 dB /100m @ 100 MHz
• Straight-through or crossover copper cable may be used.
• Shielded (STP) or unshielded (UTP) twisted-pair cable may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Crossover Cable
1
2
3
6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1
2
3
6
1
2
3
6
1
2
3
6