Assembling & Installation

CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
1) Find the appropriate threaded holes on mounting strap[1]
that align with hole distance in canopy[2] Thread mounting
screws[3] into threaded holes starting from outlet box[4] side.
2) Attach mounting strap to outlet box with strap mounting
screws[5]. Mounting strap can be adjusted to suit position of
xture.
3) Grounding instructions: (See Illus. A or B)
A) Onxtureswheremountingstrapisprovidedwithahole
and two raise dimples. Wrap ground wire from outlet box
around green ground screw, and thread into hole.
B) Onxtureswhereacuppedwasherisprovided.Put
ground wire from outlet box under cupped washer and
green ground screw and thread screw into hole in mount-
ing strap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wire to outlet box ground wire with wire connector, after follow-
ingtheabovesteps.Neverconnectgroundwiretoblackor
white power supply wires.
4) Makewireconnections.Referencechartbelowforcorrectcon-
nections and wire accordingly
5) Pushxturetowallcarefullypassingmountingscrewswith
holesincanopy.Makesureallwiresareinsidecanopyanddo
notgetpinchedbetweenwallandcanopyofxture.
6) Threadlockupknobs[6] onto mounting screws and tighten to
securexturetowall.
7) Carefullyraiseglass[7]tothexture.Slipthesmalleropening
overthesocket[8]andttheglassagainstthepadinsidethe
xtureroof[9].
8) Threadthesocketring[10]ontothesocket.Tightensocketring
tosecureglassinplace.(DONOTovertighten.)
9) Insertrecommendedbulb.(Notsupplied)
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS
AND/OR IN WET LOCATIONS.
10) Mountingsurfaceshouldbeclean,dry,atand1/4”larger
that the canopy on all sides. Any gaps between the mounting
surfaceandcanopyexceeding3/16”shouldbecorrectedas
required.
11) Withsiliconecaulkingcompound,caulkcompletelyaround
wherebackofcanopymeetsthewallsurfacetopreventwater
from seeping into outlet box.
8
9
6
7
10
4
1
2
3
5
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire