Installation Guide

51
Step 04 – Select heat pump reversing
valve option
If you have selected “HP” for heat pump
system in Step 02, this option will be
displayed.
1. Rotate the jog dial to select:
• “o” for a system in which the reversing
valve is energized in cooling.
• “b” for a system in which the reversing
valve is energized in heating.
2. Press the jog dial to confirm your selection.
Step 03 – Select fan control option
1. Rotate the jog dial to select:
• “HG” for gas heating.
• “HE” for electric heating.
2. Press the jog dial to confirm your
selection.