User manual

12
Operation and maintenance
UK
Remove all packaging of the device.
Check if the voltage of the appliance corresponds to the main voltage of your home.
Rated voltage : AC220-240V 50Hz. This device is not suitable for outdoor installation or use.
When fixed or moved, the device can not be set horizontally or declined to more then 45° or
upside-down.
Before use
Place the appliance on a flat stable surface and keep at least 30 cm. free space around it.
Make sure the unit is placed in a upright position.
Let the unit, after transport, wait for more than 4 hours before it is plugged in into the wall outlet.
Prevent the cabinet to get wet.
Make sure the power cable to the power plug is not curled up on the back of the device in the
cable storage, it can get too hot. Place the plug always into a grounded outlet.
Never place the appliance near any heat sources or direct sunlight.
Installation of the carbon filter (No. 15)
1
Remove the air filter frame (No. 5)
from the unit.
2
Separate the filter holder from the
filter frame.
3
Remove the carbon filter (No. 15)
from its plastic bag.
4
Insert the carbon filter into the
filter frame.
5
Fix the filter by reassembling the
holder onto the filter frame.
6
Re-fit the filter frame inside the
unit.
.
13
Mounting the exhaust accessories.
The air conditioning system cools the air in the room where unit is placed. The absorbed heat
of the conditioned air, should be removed to outside the room where the unit is placed.
During cooling of hot air condenswater will be created. Much of the condensation will be
transported with the warm air to outside. At high humidity not all the condense will be
transported with the warm air to the outside, the water tank must regularly be emptied.
In the chapter "Condensate Drain" is this defined step by step.
There are several ways to transport warm air out of the room:
Attach the hose (No. 10) in the warm air outlet (No. 8) of the device. Hang the hose out
the window or a door. The cooling capacity will not be optimal because of warm outside
air will flow into the to cool area.
Drill a hole of 135 mm. diameter in the outer wall and enter the tubing through the hole.
The cool capacity is now optimal.
Screw the adapter (No. 13) at the end of the hose (No. 10). Place the window spacer in
the open section of the window. Insert the adapter into the socket for the adapter (No. 12).
The cool capacity is optimal. Provide a maximum distance of 36 cm. the device to the
windows or exterior wall.
Make sure that the hose (No. 10) is not
kinked or that the air flow is obstructed.
Never extend the hose (No. 10).