Operation Manual

4
WARNING
Specic information regarding appliances with R 290
refrigerant gas.
Thoroughly read all of the warnings.
When defrosting and cleaning the appliance , do
not use any tools other than those recommended
by the manufacturing company.
The appliance must be placed in an area without
any continuously sources of ignition (for example:
open ames , gas or electrical appliances in
operation).
Do not puncture and do not burn.
Appliance shall be installed, operated and stored
in a room with a oor area larger than X m2. (X=4
for 5000Btu/h, 7000Btu/h, 8000Btu/h; X=7.7 for
9000Btu/h, 10000Btu/h, 10500Btu/h)
This appliance contains Y g (see rating label back of
unit ) of R290 refrigerant gas.
R290 is a refrigerant gas that complies with the
European directives on the environment. Do not
puncture any part of the refrigerant circuit.
If the appliance is installed, operated or stored in
a nonventilated area, the room must be designed
to prevent to the accumulation of refrigerant leaks
resulting in a risk of re or explosion due to ignition
of the refrigerant caused by electric heaters, stoves,
or other sources of ignition.
The appliance must be stored in such a way as to
prevent mechanical failure.
Individuals who operate or work on the refrigerant
circuit must have the appropriate certication
issued by an accredited organization that ensures
competence in handling refrigerants according to
a specic evaluation recognized by associations in
the industry.
Repairs must be performed based on the
recommendation from the manufacturing
company. Maintenance and repairs that require
the assistance of other qualied personnel must be
performed under the supervision of an individual
specied in the use of ammable refrigerants.
REFRIGERANT
(CE) N 842/2006: This air conditioner contains the refrigerant R290. The
amount of refrigerant is less than 1kg, and is in a closed cooling circuit.
The coolant does have zero ozone depletion potential, but is a so-called
greenhouse gases under the Kyoto Protocol and may thus contribute to
global warming, if it is released to the atmosphere. Therefore only trained
technicians with refrigerant certicate make a lling or emptying. Your air
conditioner does not have be relled with refrigerant if used properly and
has an undamaged coolant circuit. GWP: R290: 3
Instruction manual