PAC 2000 X EN TRT-BA-PAC2000X-TC-006-EN OPERATING MANUAL LOCAL AIR CONDITIONER
Legal notice Table of contents Notes regarding the operating manual .................................... 1 Information about the device................................................... 2 Technical data ........................................................................ 2 Safety ..................................................................................... 3 Transport and storage............................................................. 3 Operation...........................................
Device depiction Information about the device Device description The primary purpose of the device is room cooling. It further filters and dehumidifies the air thus creating an agreeable room climate. Additionally, the device can be used as heater. In ventilation mode the device also provides the opportunity of air circulation without cooling effect. In dehumidification mode moisture is withdrawn from the air.
Personnel qualifications Safety Carefully read the operating manual before using the device and keep it within reach! • Do not use the device in potentially explosive rooms. • Do not use the device in atmospheres containing oil, sulphur, chlorine or salt. • Set the device up in an upright and stable position. • Let the device dry out after a wet clean. Do not operate it when wet. • Make sure that the air inlet and outlet are not obstructed.
Connecting the exhaust air hose Operation • Avoid open doors and windows. • Do not exceed the recommended room size. • Keep curtains and venetian blinds closed during the sunniest time of the day. • Keep the filter clean. • Reduce the temperature and ventilation settings as soon as the room has reached the desired ambient conditions. • During cooling operation there is no need for a drain pipe being installed. Make sure that the rubber cap is positioned on the drain hole while the device is running. 1.
Discharging exhaust air Start-up • Prior to initial start-up, the battery included in the scope of delivery must be inserted in the remote control. – To do so, open the cover of the battery compartment at the back of the remote control. – Insert the battery observing the correct polarity. Go by the marking inside the battery compartment. – Then close the battery compartment. • Check air inlets and outlets for foreign objects and remove these, if necessary.
Control panel (10) (11) (17) (16) (12) (15) (14) (13) No. Designation Function 1 2 3 Power Functions Temperature control (+) 4 Temperature control (-) 5 LED display 6 SPEED Press this button to turn the device on or off. Use this button to set cooling, heating or dehumidification operating mode. Pressing this button during cooling operation increases the preset temperature by 1 °C each time it is actuated; the maximum limit is 30 °C.
Setting the operating mode • To set the operating mode, press the Functions button (2): – cooling, – heating, – dehumidifying (drying). Setting the temperature • Use the temperature control buttons (+ (3) or - (4)) to set the desired temperature. Setting the fan speed • Choose from the available speed levels by pressing the button Speed (6).
Heating Remote control • If you want to utilize the heating function, the following modification is required: All settings of the device can also be made using the remote control included in the scope of delivery. Please gather the button functions from the Control panel paragraph. 9. 9. 3. 8. 4. 2. 5. 7. 1. 6. (7) (6) 1. Detach the exhaust air hose. 2. Mount the connection piece for the exhaust air hose (6) to the cooling air outlet (7). No. Operating element Function 1. 2. 3. 4. 5. 6. 7.
Maintenance Maintenance intervals before every start-up Maintenance and care interval Empty the condensation tank Check the air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air inlet grid and air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run at least every 2 weeks as needed at least every 4 weeks at l
Activities required before starting maintenance • Do not touch the mains plug with wet or damp hands. • Before any work, remove the mains plug! Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec. Cleaning the housing Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners.
Emptying the condensation tank A. 1. First remove the rubber cap from the drain hole to drain the water. 2. After draining is completed, restart the device, then the unit can operate normally. Cleaning the air inlets and the air filter Caution! Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded.
Disposal The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com.
Produktdatenblatt / Product Fiche Lokales Klimagerät / Local Air Conditioner Artikel-Nr. / Item-No. PAC 2000 X 1.210.002.003 PRODUKTFOTO Funktion nur Kühlung / Cooling only LWA Schallleistungspegel / Sound Power Level 65 dB(A) re 1 pW Kältemittel / Refrigerant Typ / Type Gewicht / Weight - Treibhauspotenzial / Global Warming Potential g GWP t CO2 äq. - CO₂-Äquivalent / CO₂-Equivalent R-410A 450 2.088 0,94 DE Der Austritt von Kältemittel trägt zum Klimawandel bei.
Entfeuchtungsleistung / Dehumidifying Volume Betriebstemperatur / Operating Temperature Einstellbereich Temperatur im Kühlbetrieb/ Set Temperature Range Cooling Mode Einstellbereich Temperatur im Heizbetrieb/ Set Temperature Range Heating Mode max. Luftvolumenstrom / max. Air Flow Volume l/h °C °C °C m3/h Netzanschluss / Power connection Nennstrom / Nom.
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.