5 Operating manual – Local air conditioner PAC 2000 X EN
Discharging exhaust air
• The length of the exhaust air hose should not exceed 4 m.
The exhaust air hose must not be bent up or down.
• A minimum distance of 500 mm is to be observed between
the filter side of the device and the wall or other obstacles.
Start-up
• Prior to initial start-up, the battery included in the scope of
delivery must be inserted in the remote control.
– To do so, open the cover of the battery compartment at the
back of the remote control.
– Insert the battery observing the correct polarity. Go by the
marking inside the battery compartment.
– Then close the battery compartment.
• Check air inlets and outlets for foreign objects and remove
these, if necessary.
• Check the air filter for dirt and clean it, if required. Also see
chapter Maintenance.
Switching the device on
1. Insert the mains plug into a properly secured mains socket.
2. Use the power button (1) to switch the device on.
– To prolong the compressor lifetime, wait for at least
3.5 minutes after switch-off before switching the device
back on.