5 Operating manual – Local air conditioner PAC 2000 X EN
Discharging exhaust air
The length of the exhaust air hose should not exceed 4 m.
The exhaust air hose must not be bent up or down.
A minimum distance of 500 mm is to be observed between
the filter side of the device and the wall or other obstacles.
Start-up
Prior to initial start-up, the battery included in the scope of
delivery must be inserted in the remote control.
To do so, open the cover of the battery compartment at the
back of the remote control.
– Insert the battery observing the correct polarity. Go by the
marking inside the battery compartment.
Then close the battery compartment.
Check air inlets and outlets for foreign objects and remove
these, if necessary.
Check the air filter for dirt and clean it, if required. Also see
chapter Maintenance.
Switching the device on
1. Insert the mains plug into a properly secured mains socket.
2. Use the power button (1) to switch the device on.
To prolong the compressor lifetime, wait for at least
3.5 minutes after switch-off before switching the device
back on.