Operation Manual

EN Operating manual – Local air conditioner PAC 2000 X 8
Heating
If you want to utilize the heating function, the following
modification is required:
1. Detach the exhaust air hose.
2. Mount the connection piece for the exhaust air hose (6) to the
cooling air outlet (7).
3. Fit the exhaust air hose to the connection piece (6).
4. Align the pivotable nozzle.
Start heating function
Press the functions button (2) until the LED for heating (16)
lights up.
The device will start after a few seconds.
Note:
Heating is possible up to a max. ambient temperature of 25 °C.
At an ambient temperature of more than 25 °C the heating
function will not start.
Remote control
All settings of the device can also be made using the remote
control included in the scope of delivery. Please gather the button
functions from the Control panel paragraph.
Shutdown
1. Use the power button (A) to switch the device off.
2. Remove the mains plug from the mains socket.
3. Clean the device, and especially the air filter, according to
chapter Maintenance.
4. Store the device according to the Storage chapter.
The device has been checked for proper functioning several times
during production. If malfunctions occur nonetheless, check the
device according to the following list.
Your device still does not operate correctly after these
checks?
Bring the device to a specialist company for cooling and
air-conditioning or to Trotec for repair.
(6)
(7)
No. Operating element Function
1. Power Power button
2. Func Operating mode selector
3. Timer Timer switch
4. Auto Automatic fan speed
5. Hi High fan speed
6. Mid Medium fan speed
7. Low Low fan speed
8. Sleep Sleep control function
9. Temp Temperature control
Errors and faults
Display indica-
tion
Cause Troubleshooting
E1 Short circuit on both
temperature sensor and
PCB.
Contact an electrician for
repair.
E2 Short circuit on
temperature sensor copper
tube and PCB wiring.
Contact an electrician for
repair.
ALARM / E4 Indicates full water tank or
poor contact of the signal
plug.
Drain water.
See Emptying the
condensation tank on
page 11.
1.
9.
8.
2.
7.
6.
5.
4.
3.
9.