TVE 10 / TVE 11 / TVE 15 / TVE 17 EN TRT-BA-TVE10-TVE11-TVE15-TVE17-TC-004-EN OPERATING MANUAL TABLE FAN
You can download the current version of the operating manual and the EU declaration of conformity via the following link: Table of contents Notes regarding the operating manual................................. 1 Safety ..................................................................................... 1 Information about the device................................................ 3 TVE 10 / TVE 11 Transport and storage........................................................... 3 Assembly and start-up...
• • • • • • • • • • • • • • • This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation. Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts. Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals).
Information about the device Transport and storage Device description The table fans of the TVE series are suitable for indoor air circulation. The devices TVE 10 / TVE 11 / TVE 15 / TVE 17 have the following features: • 2 (TVE 10 / 11) or 3 (TVE 15 / 17) speed levels • Inclination angle of the fan head vertically adjustable by up to 30° • On-demand 80° oscillation • Carrying handle for easy transport Device depiction Transport Before transporting the device, proceed as follows: • Switch off the device.
Assembly and start-up Start-up Scope of delivery When positioning the device, observe the minimum distance from walls or other objects as described in the Technical data chapter. • • 1 x Device TVE 10 / TVE 11 / TVE 15 / TVE 17 1 x Manual A Unpacking the device C 1. Open the cardboard box and take the device out. 2. Completely remove the packaging. 3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.
Using the oscillation function By means of the oscillation function you can achieve consistent ventilation. ü The device is switched on and operating. 1. Press the oscillation pin (2) so that it locks in place. Operation Operating elements TVE 10 / 11 0 1 2 2 18 17 90° 80° TVE 15 / 17 0 1 ð The oscillation function is activated. ð The fan head rotates to and fro by up to 80°. 2. Pull the oscillation pin (2) up to switch the oscillation function back off.
Errors and faults Maintenance The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list. The device does not start: • Check the power connection. • Check the power cable and mains plug for damages. • Check the on-site fusing. • Check whether the overheating protection has tripped, see chapter Safety. • Wait for 10 minutes before restarting the device.
Technical annex Disposal Technical data Parameter Value Model TVE 10 / TVE 11 TVE 15 / TVE 17 Fan stages 2 3 Air velocity 2.79 m/s 2.93 m/s Input voltage 220 - 240 V / 50 Hz 220 - 240 V / 50 Hz Power consumption 25 W 40 W Power cable length 1.80 m 1.80 m Adjustable inclination angle 30° 30° Oscillation function 80° 80° Fan blade diameter 23 cm 40 cm Sound pressure 50 dB(A), level 2 level (1 m distance) 57 dB(A), level 3 Weight 1.5 kg 2.
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.