Use and Care Manual

Not for
Reproduction
10 troybilt.com
Moving Generator
1. Remove handle pin (A) from bracket on right side
of handle (viewing generator from engine end).
2. Pull folding handle to the upright position until
latch (B) locks into place.
3. Reinsert handle pin in bracket on right side of handle.
4. Place your foot onto the axle (C) located under
the recoil starter and pull back on the handle.
5. Always face generator and push or pull to desired
location. When moving generator on an incline,
always make sure you are uphill from generator.
6. Place foot on axle and gently let generator tip
forward to rest on support leg.
7. Remove handle pin from right side of handle.
8. Pull up on latch and push handle forward to fold
down handle.
Verify Engine Oil Level
The generator engine is shipped from the factory filled
with oil (API SJ or higher 10W-30). This allows for
generator operation in the widest range of temperature
and climate conditions. Before starting the engine,
check oil level and ensure that engine is serviced as
described in Maintenance.
NOTICE Any attempt to crank or start the engine
before it has been properly filled with the recommended
oil could result in equipment failure.
Refer to Maintenance for oil fill information.
Damage to equipment resulting from failure to follow this
instruction will void warranty.
NOTICE See Oil in the Maintenance section to review
oil recomendations. Verify provided oil in engine is the
correct viscosity for current ambient temperature.
Add Fuel
Fuel must meet these requirements:
Clean, fresh, unleaded gasoline.
A minimum of 87 octane/87 AKI (91 RON). For
high altitude use, see High Altitude.
• Gasoline with up to 10% ethanol (gasohol) is
acceptable.
NOTICE Use of unapproved fuels could damage
generator and voids warranty.
DO NOT use unapproved gasoline such as E15 and E85.
DO NOT mix oil in gasoline or modify engine to run on
alternate fuels.
C
WARNING Body Crush/Tip Over Hazard.
Generator could tip over while moving
resulting in serious injury.
Handle pin must be installed prior to moving generator.
A
B
WARNING Fuel and its vapors are extremely
flammable and explosive which
could cause burns, fire or explosion
resulting in death or serious injury.
WHEN ADDING FUEL
Turn generator engine OFF and let it cool at least 2
minutes before removing fuel cap. Loosen cap slowly to
relieve pressure in tank.
Fill fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting
engine.
Keep fuel away from sparks, open flames, pilot lights,
heat, and other ignition sources.
Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
DO NOT light a cigarette or smoke.