Use and Care Manual

Not for
Reproduction
16 troybilt.com
Control Panel
A - 120 Volt AC, 20 Amp, GFCI Duplex Receptacles
— May be used to supply electrical power for the
operation of 120 Volt AC, 20 Amp, single phase,
60 Hz electrical, lighting, appliance, tool and motor
loads.
B - On/Off Switch — Set this switch to ON (I) before
starting engine. Set switch to OFF (0) to shut off
engine.
C - Battery Float Charger Jack — Use battery float
charger jack to keep the starting battery charged
and ready for use.
D - Display Button — Push to scroll through LCD
screens on Extend-a-panel™. Also push and hold
for a minimum of 3 seconds to reset maintenance
reminders and security features.
E - Choke Control — Used when starting a cold
engine.
F - Start Switch — Push and hold in “Start” position
for a maximum of 5 seconds during each start
attempt, until engine starts.
G - Circuit Breakers (AC) — The 120 Volt AC, 20A
GFCI duplex receptacles are provided with “push
to reset” circuit breakers to protect the generator
against electrical overload.
H - Rocker Switch Main Circuit Breaker — The
120/240 Volt AC, 30A locking receptacle is
provided with a rocker switch circuit breaker to
protect generator against electrical overload.
J - 120/240 Volt AC, 30 Amp Locking Receptacle
— May be used to supply electrical power for the
operation of 120 and/or 240 Volt AC, 30 Amp,
single phase, 60 Hz electrical, lighting, appliance,
tool and motor loads.
K - Rocker Switch Cordset Circuit Breaker — The
cordset on main panel is provided with a double
pole rocker switch circuit breaker to protect
generator against electrical overload.