F6179 JUNIPER LARGE CHANDELIER INSTALLATION INSTRUCTIONS
TROY LIGHTING
FIXTURE PREPARATION
1. Remove the fixture, parts and parts bag(s) from the carton.
NOTICE:
Before discarding the carton, double check to
make certain that all parts are found.
CAUTION
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH
ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES.
INSTALLATION AND MAINTENANCE OF THIS UNIT REQUIRES AN ELECTRICIAN OR
CERTIFIED FACTORY TRAINED TECHNICIAN.
If an existing fixture is being replaced, remove it and note to which of the wires in the outlet box the fixture was attached.
DO NOT SEPARATE ANY OTHER WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE THE INSULATION OF OLDER WIRING.
In regular circumstances the BLACK wire will be the "Hot" lead and the WHITE wire will be the "Neutral" or "Common" lead
A GREEN or BARE COPPER wire is the "Ground". In older buildings it is always good practice to reconfirm the polarity of the wiring.
FIXTURE INSTALLATION
1. Attach the mounting strap to the outlet box. (The green screw should face the floor).
2. Remove the threaded ring from the screw collar loop. Fully thread the screw collar loop
onto the nipple. Thread the hex nut onto the nipple and the nipple into the mounting strap.
Place the canopy over the screw collar and against the ceiling. Adjust the nipple so that
1
4
"
of threads on the screw collar loop extend beyond the canopy. Tighten the hex nut against
the crossbar. Using the threaded ring, install the canopy. See Figure 1.
NOTICE
The important safeguards and instructions outlined on this sheet cannot cover all possible conditions and situations that
may occur. it must be understood that common sense, caution and care factors that cannot be built into any product.
Caution and care must be supplied by the person(s) installing, operating and caring of this lighting fixture.
This fixture is designed to be mounted on a correctly installed standard round or octagon box or a through wiring box with a
plaster frame. The box must be securely mounted to the structure of the building. The crossbar and hardware supplied should be
used. directly mounting the fixture to the outlet box may make it impossible to correctly align the fixture.
NOTICE:
CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO
CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
Canopy
Nipple
Hex nut
Screw Collar loop
Ring
Green screw
Mounting Strap
Outlet box
FIGURE-1
WARNING
DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.