Section 4: Operation
the Engine
I. Turn OFF and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with
electrical devices plugged in and turned ON.
2. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
3. Turn engine off according to instructions given in the
engine operator's manual.
4. Move fuel valve to "Off" position.
REC EPTACLES
CAUTION 1
NEVER attempt to power a device requiring more amperage
than generator or receptacle can supply.
DO NOT overload the generato_ See "Don't Overload
Generator _',
1201240 Volt AC, 30 Amp, Locking
Receptacle
Use a NEMA LI 4-30 plug with this receptacle. Connect a
4-wire cord set rated for 250VoItAC loads at 30Amps (or
greater) (Figure 5).You can use the same 4-wire cord if you
_lan to run a 120Volt load.
4-Wire Cord Set
/ \
(Neutral)
IIIIII
t,o t x/.o,
NEMA L14-30 F7L7 Ground (Green)
This receptacle powers 120/240VoItAC, 60 Hz, single
phase loads requiring up to 5,550 watts of power
(5.55 kW) at 23. I Amps for 240Volts or two independent
120Volt loads at 23. [Amps each.The outlet is protected
by a double pole rocker switch circuit breaker.
120 Volt AC, 20 Amp, Duplex
Receptacles
Both duplex receptacles (Figure 6) are protected against
overload by a double pole rocker switch circuit breaker.
: -_ _" D D D- "- -D. -
@
Use each receptacle to operate 120VoltAC, single-phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
(3EN ERATOR ADAPTER
CORD SET
The generator comes with a 25' generator adapter cord set
designed to provide two sets of 120Volt, 20Amp outlets from
one 120Volt, 20Amp duplex receptacle (Figure 7).
- - - , "g,D - ® g -
The maximum load on each outlet is 20 Amps.The
maximum total load on both black wire outlets or white
stripe wire outlets is 20 Amps.
NOTE: Follow all safety precautions when connecting any
extension cord or device to the generator.