Manual

Maintenance
SPECiFiCATiONS
Starting Wattage ....................... 8,550 watts
Wattage ............................. 5,550 watts
AC Load Current:
At 120Volts ......................... 46.2 Amps
At 240Volts ......................... 23.1 Amps
Phase .................................. l-phase
Rated Frequency ......................... 60 Hertz
Fuel Tank Capacity .................... 5 U.S. gallons
Shipping Weight .......................... 170 Ibs.
GENERAL HAINTENANCE
RECOHHENDAT|ONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.
NOTE: Should you have questions about replacing
components on your Troy-Bilt generator, please call
1-888-61 1-6708 for assistance.
Engine Maintenance
See engine operator's manual for instructions.
I A CAUTiO.
" Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
, Thoroughly wash exposed areaswith soap and water;
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OILTO COLLECTION CENTERS.
i
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems, in
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
WARNING
WHEN ADJUSTING OR MAKING REPAIRSTOYOUR
GENERATOR
" Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug teste_:
DO NOT check for spark with spark plug removed.
Generator Cleaning
Use a damp cloth to wipe exterior surfaces clean.
CAUTION
DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insert any objects through cooling slots.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a vacuum cleaner to pick up loose dirt and debris.
Inspect cooling air slots and opening on generator.These
openings must be kept clean and unobstructed.
O