Datasheet

Distributed by Conrad Electronic SE • Klaus-Conrad-Str. 1 • D-92240 Hirschau
Datasheet
Item no. TC-TS18-05N-1,2, TC-TS18-05P-1,2
TC-TS18-08N-1,2, TC-TS18-08P-1,2
V1_09062017_01_en
3
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the
prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represents the technical status at the time of printing.
© Copyright 2017 by Conrad Electronic SE.
Item
Shield
Non - Shield
Cable type
Cable type
Output Function
Output Stage
NPN NO - output
TS18-05N-1
TS18-08N-1
NPN NC - output
TS18-05N-2
TS18-08N-2
PNP NO - output
TS18-05P-1
TS18-08P-1
PNP NC - output
TS18-05P-2
TS18-08P-2
Sensing distance
5 mm ± 10%
8 mm ± 10%
Setting distance
0 to 4.0 mm
0 to 6.4 mm
Response frequency
1.5 KHz
Standard target
18 x18 x1 mm
Body material
Brass nickel plated
Circuit protection
Yes
Reverse polarity protection of
supply voltage
Yes
Cable length
2 M