Product Manual

............ www.truemfg.com ............
True Food Service Equipment, Inc.
20 20
1
2
3
4
LAE Electronic Control
Info/Set Point
Button
Manual Defrost/
Down Button
Manual Activation/
Up Button
Stand-By
Button
Compressor
Running
Activation of 2nd
Parameter Set - NA
Alarm - NA
Cabinet in Defrost
Evaporator Fan
Running
LAE Control Icons
WHY:
THE DEFROST INTERVAL IS THE TIME DURATION BETWEEN
DEFROST CYCLES.
The Defrost Interval time starts when the cabinet is supplied
power or after a manual defrost.
HOW:
A. Toseethesetpoint,pressandholdtheinfobutton
andthestand-bybuttonatthesametime.
“ScL”willappear.Seeimage1.
B. Pushtheupbuttonuntil“dFt”appears.
Seeimage2.
C. Pressandholdtheinfobuttontoseethe
defrostintervaltime”.Seeimage3.
D. Whilepressingandholdingtheinfobutton,
presstheupordownbuttontochangethe“defrost
intervaltimes”(higherthenumberthelessfrequentthe
cabinetwilldefrost).
E. Oncethe“defrostintervaltime”hasbeenchanged,
releasetheinfobutton.
Wait30secondsforthedisplaytoshowtemperature.
Seeimage4.
andthestand-bybuttonatthesametime.
HOW TO CHANGE “DEFROST
INTERVALS
andthestand-bybuttonatthesametime.
Pressandholdtheinfobuttontoseethe
releasetheinfobutton.
Whilepressingandholdingtheinfobutton,
May need to unlock control.
This can only be changed if defrost mode parameter “DFM” is set for “TIM”.