Use and Care

1111
True Food Service Equipment, Inc.
............ www.truemfg.com ............
INSTALLATION / OPERATION INSTRUCTIONS
A. Thecompressorisreadytooperate.Pluginthe
cooler.
B. TemperaturecontrolsetatNo.4positiongives
refrigeratorsanapproximatetemperatureof35°F.
Allowunittofunctionseveralhours,completely
coolingcabinetbeforechangingthecontrolsetting.
C. Excessivetamperingwiththecontrolcouldleadto
servicedifficulties.Shoulditeverbecomenecessary
toreplacetemperaturecontrol,besureitisordered
fromyourTRUEdealerorrecommendedservice
agent.
D. GoodairflowinyourTRUEunitiscritical.Be
carefultoloadproductsothatitneitherpresses
againstthebackwall,norcomeswithinfourinches
oftheevaporatorhousing.Refrigeratedairoffthe
coilmustcirculatedownthebackwall.
NOTE
If the cooler is disconnected or shut off, wait five minutes
before starting again.
RECOMMENDATION
Before loading product we recommend you run your TRUE
unit empty for two to three days. This allows you to be sure
electrical wiring and installation are correct and no shipping
damage has occurred. Remember, our factory warranty
does not cover product loss!
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial number for
your cooler. If at any time during the life of your cooler, a
part is needed, you may obtain this part by furnishing the
model number and serial number to the company from
whom you purchased the cooler. Call Toll-Free: (800)-424-
TRUE (Direct to Parts Department). (800)-325-6152 (U.S.A.
& Canada only) or call: (636)-240-2400.
WARNING
REMOVAL OF BAFFLES IN CONDIMENT PAN AREA WILL
ADVERSELY AFFECT REFRIGERATION PERFORMANCE.
PLEASE LEAVE THE BAFFLES IN THE CORRECT LOCATION.
(See images below)
STARTUP
AIR-FLOW THROUGHOUT CABINET (TPP UNITS ONLY!)
Baffle in the correct location.