Use and Care

1212
True Food Service Equipment, Inc.
TERMS
Cut-out-Temperaturesensed
bythecontrollerthatshutsthe
compressoroff.
Cut-in-Temperaturesensedbythe
controllerthatturnsthecompressor
on.
REQUIRED TOOLS
•PhillipsHeadScrewdriver
•5/64”or2mmAllenWrench
•T-7TorxWrench
STEP 1
Unplugthecooler.
STEP 2
Removethescrewsthatsecurethe
temperaturecontroltotheinsetbox
lowerleftsideofthecabinet(when
facingthefrontofthecabinet).
STEP 3
Pulloutgentlyfromcabinet.
STEP 4
Forhighelevationinstallations,it
maybenecessaryto“warm-up”the
setpoints.Tomaketheadjustment,
inserttheappropriatetoolineach
adjustmentscrewandturn1/4ofa
revolutionclockwise(totheright).
Thisprocedurewilladjustboth
thecut-inandcut-outabout2°F
warmer.
STEP 5
Makesuretoreconnectthepink
wiretotheproperspade
terminalwhenreinstalling.
............ www.truemfg.com ............
INSTALLATION / OPERATION INSTRUCTIONS
NOTE
Mechanical temperature
controllers are affected when
functioning at high altitude.
The cut-in and cut-out
temperatures will be colder than
when the controller functions closer
to sea level.
Danfoss Temperature Control
(High Altitude Only!)
Cut-outAdjustmentScrewAllen(5/64”
or2mm)(clockwiseforwarmer)
Cut-inAdjustmentScrewTorx(T-7)
(clockwiseforwarmer)
CompressorConnection(pink)
CompressorConnection(pink)
TEMPERATURE CONTROL ADJUSTMENT FOR
HIGH ALTITUDE ONLY!
TEMPERATURE CONTROL LOCATION AND
SETTING - TFP UNITS ONLY
TFP Temperature control is located on
the back of the unit.
Set control to 5.