Operation Manual

10
Change of fuse (only TEB-3 – 12 V)
Observe the ESD-regulations!
The fuse (F1) is located on the electronic control unit in
the device.
Disconnect the fan from the power source (disconnect
battery, or remove mains plugs).
Remove the power supply plug and control panel plug.
Unscrew the 2 screws (1) on the housing – remove housing.
Touch the PCB on the edge and remove from the device.
Only replace faulty fuses with ones of the same type
(see “Technical Data”).
Insert the PCB into the housing.
After replacing the fuse, attach the housing to the fan using
the 2 screws (1).
Connect the plug of the control panel and the power cable
plug (check that the unit is wired correctly – otherwise the
control panel will not function and the fan will rotate in the
wrong direction.).
Connect the battery again; if necessary reconnect the
power supply.
F1
1
TN-3 – 230 V
External control panel
1
2
3
4
5
230 V ~
Trumavent
d
c
a
b
a = Knob for setting fan output (1 – 5)
b = Knob for the operating types
c = Off
d = On, manual setting of the fan output
Set required speed using the knob (a).
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.