User Manual

31
www.tytusgrills.com
TYTUS 4-Burner Gas Grill & 4-Burner Island Gas Grill
PURGE AIR FROM THE GAS LINE/RESET THE REGULATOR
1) Turn the control knobs OFF.
2) Turn off the gas at the tank valve.
3) Disconnect the regulator from propane tank.
4) Let the gas line and regulator stand for five minutes to allow air to purge.
5) Reconnect the regulator to the propane tank.
6) Turn the tank valve on SLOWLY 1/4 of a turn.
7) Open the grill lid.
8) Push and turn the left main burner control knob to H
I.
Note: This procedure should be done every time a new propane gas tank is connected to your
grill.
WARNING: Should a "FLASH-BACK" fire occur in/or around the burner tubes, follow the
instructions below. Failure to comply with these instructions could result in a fire or explosion
that could cause serious bodily injury, death, or property damage.
Shut off the gas supply to the grill.
Turn the control knobs to the O
FF position.
Put out any flame with a Class B fire extinguisher.
Open the grill lid.
After the grill has cooled down, clean the burner tubes and burners. See
Burner Tubes
and Burner Ports” (page 45) for instructions.
WARNING: If ignition does not occur in five seconds, turn the control knob(s) and gas source
OFF and conduct a leak test as explained in Check for Gas Leaks” (page 30). If no leaks are
detected, wait five minutes for any gas to clear and repeat the lighting procedure.
Tytus-Grills_19-0238_MAN_V1_ENG.fm Page 31 Friday, August 9, 2019 10:44 AM