Use and Care Guide Clear Ice Maker Model: CLR2160 Clear Combo® Ice Maker/Refrigerator Model: CLRCO2175 CLR2160 CLRCO2175
Introduction Congratulations on your purchase of a U-Line refrigeration product. A pioneer in the field for more than 40 years, U-Line Corporation is the world’s number one manufacturer of built-in, under-counter, specialty refrigeration and ice making products. U-Line dedicates 100% of its research and development to these products. The result: U-Line technology consistently leads the market with innovation, design, depth of product line and performance.
TABLE OF CONTENTS Introduction .................................................................................................. Inside Front Cover Warranty Registration .................................................................................. Inside Front Cover Please Record Your Model Information ...................................................... Inside Front Cover 1-Safety Precautions ...........................................................................................................
1 SAFETY PRECAUTIONS IMPORTANT WARNING PLEASE READ all instructions completely before attempting to install operate or service your unit. • Proper installation procedures must be followed if this unit is being initially installed, or is moved to a new location after being in service. An INSTALLATION GUIDE for your unit, providing complete installation information is available from U-Line Corporation directly, and must be consulted before any installation is begun.
the Echelon™ stainless steel units from other heavier “commercial” looks. 2 PRODUCT FEATURES • An optional commercial handle is available through the dealer to further customize your unit. CLR2160 Clear Ice Maker • This model produces up to 60 lbs (27.2 kg) of ice per day, will store 30 lbs (13.6 kg). • Stainless steel model is deemed suitable for outdoor use by UL. • An electronic control panel with digital display allows you to control all operating functions.
5 INSTALLATION Prepare Plumbing CAUTION Plumbing installation must observe all state and local codes. All water and drain connections MUST BE made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm. Water Supply Connection When connecting the water supply, follow these guidelines: • Review the local plumbing codes before you install the unit. • Connect to the cold water supply.
Drain Connection If using a Gravity Drain: 1. Slide 2 hose clamps onto the drain connection on the rear of the appliance. IMPORTANT Drain can NOT be located directly below unit. Unit has a solid base that will not allow unit to drain below itself. The CLR2160 or CLRCO2175 can be installed using a Gravity Drain, a Factory-Installed Drain Pump (U-Line P60) or a Locally-Installed (U-Line P60) Drain Pump. Drain lines must have a 5/8” inside diameter.
Factory-Installed Drain Pump If your drain line will run up to a stand pipe, disposal assembly or spigot assembly or does not otherwise meet the requirements for a Gravity Drain, you may have ordered the CLR2160 or CLRCO2175 with a U-Line P60 Drain Pump. See Figures 8, 9 and 10 for typical installations requiring a Drain Pump. If you need to install a P60 Drain Pump into your unit, see Locally-Installed Drain Pump on Page 6. 4.
• It must have a check valve in the discharge line to prevent waste water return to the pump. Y-Branch Tailpiece P60 Pump Required Air Gap (Optional Hook-Up) • It must have an overflow protection control which will shut off power to the ice maker in the event of a pump failure. • It must have an operating temperature range of 50°F to 110°F (10°C to 40°C).
Final Water/Drain Connection 1. Connect the water supply fitting by screwing the brass garden hose fitting to the watervalve in the rear of the unit. 2. Tighten this fitting with pliers. Note: Do not use Teflon tape or joint compound on this fitting. The rubber washer provides an adequate seal. Other materials could cause blockage of the valve. 7. While pushing the unit into the opening, continuously reroute the drain tube to avoid kinks.
6 ELECTRICAL SPECIFICATIONS 7 INITIAL STARTUP Note: Unit is shipped in the “ON” position and only needs to be plugged in to start up. CAUTION Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three-prong), polarized receptacle that has been placed by a qualified electrician. The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current).
and will correct itself within the first 24 hours of operation. 3. Re-install the evaporator cover. DISPLAYING INTERIOR REFIGERATOR TEMPERATURE - MODEL CLRCO2175 ONLY 1. Touch and hold the WARMER icon (Figure 16) for approximately five seconds and release when the °F symbol in the display begins to flash. Note: On CLRCO2175 model, after the first slab of ice is produced, ice production will stop until the refrigerator side reaches the setpoint temperature, then ice production will begin again. 2.
10 OUTDOOR USAGE Light Some U-line models are designed to operate in outdoor environments. For best performance, keep the unit out of direct sunlight. If the unit will be shut off for five days or more, prop the door open to allow for air circulation and prevent mold and mildew. Figure 17 9 NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to proved high thermal efficiency and maximum sound reduction for the internal working components.
5. Reconnect power to the unit and allow it to run for one hour (minimum) until any remaining ice has been ejected from the ice maker assembly. 6. Disconnect power to the unit, dry any remaining water from the ice maker assembly, and reconnect any lines removed from the water supply valve. 7. Disconnect the power cord from its outlet and leave it disconnected until the unit is returned to service.
Condenser Cleaning WARNING DO NOT use any type of electrical heating device, ice pick, knife or other sharp instrument to defrost; this could damage the inner lining or refrigeration system and void the warranty. INTERVAL - EVERY 3 MONTHS To maintain operational efficiency, keep the front grille free of dust and lint and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.
plumber to test the water quality and recommend appropriate treatment. Evaporator cover WARNING Wear rubber gloves and safety goggles and/or face shield when handling Ice Machine Cleaner. CAUTION Use only U-Line Ice Machine Cleaner (Part No. 41978, available from your dealer or direct from your local parts distributor. To locate a parts distributor near you, visit www.U-LineService.com. It is a violation of federal law to use this solution in a manner inconsistent with its labeling.
8. When water begins flowing over the evaporator (approximately 3 minutes), pour 1 packet of CLR cleaner into the water trough. The cleaning process will last approximately 45 minutes. Ice Cube Thickness Adjustment INTERVAL - AS REQUIRED Ice thickness adjustments are made using the control panel as follows: 1. To enter the thickness adjustment mode: a. Touch and hold the UP ARROW button. b. Touch and release the DOWN ARROW button three times, then release the UP ARROW button. c.
1/16" TO 1/8" ICE BRIDGE 1/4" TO 1/2" DIMPLE BRIDGE TOO THICK BRIDGE TOO THIN DIMPLE TOO DEEP GOOD LITTLE OR NO DIMPLE BAD ULIN_0300_A Cube Types Figure 25 Leveling IMPORTANT It is extremely important that Clear Ice models are level. If not level, the ice mold will not fill evenly.
Door Alignment Check and Adjustment Slotted mounting holes IMPORTANT When properly aligned: • The door will not be flush with the top of the cabinet. The top edge of the door will be 1/8” (3.175 mm) below the cabinet top. • The door gasket will be firmly in contact with the perimeter of the cabinet and not pinched on the hinge side of the door. The following procedure will correct for up to 1/4” misalignment: 1/8" (3.175 mm) toward outside of door toward inside of door Figure 31 ULIN 0201 A 3.
Door Reversal - Black and White Models Only Metal hinge plugs ULIN_0002_A Figure 35 2. Remove metal hinge plugs (three each, top and bottom) (Figure 35) from new hinge location. Do not discard. 3. Remove top hinge (three screws) and reinstall hinge screw pin (Figure 34). ULIN_0015_A Figure 33 Black and white units may be left- or right-hand opening. Stainless steel unit doors cannot be reversed. The doors are easily reversed by moving the hinge hardware to the opposite side.
5. Remove the two door closer inserts (Figure 37) from the existing bottom hinge and install as shown on the new bottom hinge (Figure 36). 6. Remove existing bottom hinge (three screws) and remount on opposite side TOP. Remove hinge screw pin. 7. Remove the plastic hole plug from the top of the door to allow the pivot pin to be inserted in the new location. Install the plug into the vacated hole on the opposite side. To install the door shelf: 1.
1. Grasp the edges of the light housing lens opposite the exposed tab, and gently push the lens towards the tab (Figure 41). 14 TROUBLESHOOTING GUIDE 2. Pull the edge of the lens down and swing it out of the light housing. IMPORTANT ALWAYS use a genuine U-Line replacement bulb (Part No. 31317) in the light housing. Use of any other bulb within the housing will generate excessive heat, causing damage to the light housing and cabinet interior, and compromising the precise temperature control of your unit.
PROBLEM POSSIBLE CAUSE REMEDY Fresh food section too cold (Model CLRCO2175) Temperature control set too cold Use the temperature controller to set temperature warmer. Unit runs but no ice is produced. No water being supplied to the unit Check to see that water is connected and turned on to the unit. Unit runs but produces very little ice. Dirty condenser coils Clean the condenser (See MAINTENANCE; CONDENSER CLEANING). High air temperature around unit Surrounding air temperature of over 90°F.
15 ELECTRONIC CONTROL QUICK GUIDE All Models Task Touch Turn ON/OFF Hold 10 seconds Touch and release View Actual Temperature Hold 5 seconds Change °F-°C Hold Blackout Mode Display Release when °F flashes. or or or Adjust Temperature Touch Comment Touch to change temperature °F flashes after first touch, set-point saved after 5 seconds of inactivity and °F stops flashing.* Release when °F flashes. For Wine Coolers, see Use and Care Manual. Hold 10 seconds or Repeat to switch back.
This page intentionally left blank.
This page intentionally left blank.
U-Line Corporation Limited Warranty U-Line Corporation warrants each U-Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase; and warrants the sealed system (consisting of the compressor, the condenser, the evaporator, the hot gas bypass valve, the dryer and the connecting tubing) in each U-Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase.
For General Inquiries: P.O. Box 245040 Milwaukee, Wisconsin 53224-9540 U.S.A. Phone (800) 779-2547 FAX (414) 354-5696 www.U-Line.com For Service and Parts Assistance: Phone (800) 779-2547 (414) 354-0300 FAX (414) 354-5696 Email: OnLineService@U-Line.com www.U-LineService.com E-mail: OnlineParts@u-line.com For more than four decades, U-Line has distinguished itself as the leader in built-in under-counter ice making, refrigeration and wine storage appliances.