MSDS

1092528
-
ZAR Oil Based Wood Stain
Revision Date 18-Apr-2013
_____________________________________________________________________________________________
_____________________________________________________________________________________________
Page
2
/
7
Solvent naphtha (petroleum), medium aliphatic 64742-88-7 40-70
Linseed oil, polymer with Maleic anhydride and
Pentaerythritol
67922-98-9 40-70
Iron oxide 1309-37-1 7-13
Kerosene 8008-20-6 5-10
Raw umber 12713-03-0 5-10
Nepheline syenite 37244-96-5 3-7
Iron oxide yellow 51274-00-1
1 - 5
Ferric oxide black 1317-61-9 1
- 5
Iron oxide 1332-37-2
1 - 5
Carbon black 1333-86-4
1 - 5
Titanium dioxide 13463-67-7 1
- 5
4. FIRST AID MEASURES
General Advice
I
mmedia
t
e medical attention is required. Show this safety data sheet to the doctor in
attendance.
Eye Contact Immediately flush with plenty of water. After initial flushing, remove any contact lenses and
continue flushing for at least 15 minutes. Keep eye wide open while rinsing. If symptoms
persist, call a physician.
Skin Contact
Wash off immediately with plenty of water.
Inhalation
Move to fresh air. Consult a physician. If breathing is irregular or stopped, administer artificial
respiration
.
Avoid direct contact with skin. Use barrier to give mouth-to-mouth resuscitation.
Ingestion
Rinse mouth. Drink plenty of water. If symptoms persist, call a physician. Do NOT induce
vomiting.
Notes to Physician
Treat symptomatically.
Protection of First-aiders
Remove all sources of ignition.
5
.
FIRE-FIGHTING MEASURES
Flammable Properties
F
lammable
;
may be ignited by heat, sparks or flames. Flammable
liquid.
Flash Point
40C / 104F
Suitable Extinguishing Media
Use extinguishing measures that are appropriate to local
circumstances and the surrounding environment. Dry chemical.
Carbon dioxide (CO2). Water spray. Alcohol-resistant foam.
Uniform Fire Code
Combustible Liquid: II
Hazardous Combustion Products
Carbon oxides.
Explosion Data
Sensitivity to Mechanical Impact
No.
Specific Hazards Arising from the Chemical Keep product and empty container away from heat and sources of
ignition. Risk of ignition.
Sensitivity to Static Discharge
Yes.
Protective Equipment and Precautions for Firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective
gear.