Table of Contents 2 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 SM-Rib Important Information Installation Information Technical Information Trims and Flashings Illustration Roofing Installation Details Fascia Cover (FC-5/FC-7/FC-9) Eave Drip (ED-1) Eave Flashing (EF-3) Preformed Valley (PV-1/PV-2) End Wall Flashing (EW-1) Side Wall Flashing (SW-1) Transition Flashing (TF-1) Gambrel Flashing (GF-1) Gable Rake (GR-2) Gable Rake (GR-4) High Side Eave (HS-2) Hip Cap
Miami-Dade County and Local Code Compliance Southeastern Metals’ 26 Gauge SM-Rib products are Miami-Dade County approved and comply with the most recent testing requirements. Contact our technical department for a copy of our current Miami-Dade County NOA compliance report if one is required for your purposes. Important Information Finishes 40-year warranted SemCoat Plus is a fluoroceram premium coating manufactured by BASF/Morton International Inc.
Delivery, Handling and Storage Proper care in storing and handling metal panels is essential in providing you with years of service. Panels should be installed immediately to prevent storage oxidation or paint peel. Any panels not immediately installed must be kept dry and stored in an indoor area. Extreme caution should be taken in order to prevent moisture penetration of the stack(s) by rain, snowfall or condensation.
Installation Information Panel There are three critical measurements involving roof panels: the length required at the eave, the peak end and the amount of panel lap (if required). In each case a certain measurement is required. Check each measurement to ensure panel placement gives you the distance required at the eave, peak and endlap condition (if required). In most cases any variance can be taken out at the eave and peak.
Technical Information SM-Rib Panel Accelerated Testing of coating 2000 hours per ASTM G23. Salt Spray testing of coating 1000 hours per ASTM B117. Fire Testing per ASTM E108 or UL790. Wind Driven Rain Test per TAS 100. Code Approvals 1 UL Fire Resistance Directory # R20735 Miami Dade Code Approval NOA # 09-0630.11 Florida Building Code Approval # FL-11931.2 (26 Gauge) # FL-11937.
Trims & Flashings 4 6 15 3 7 5 2 8 1 12 14 1 5 3 Ridge Cap RC-2 SM-Rib Eave Drip/Eave Flashing ED-1/EF-3 2 4 Double Angle DA-1 Ridge/Hip Cap RC-1/RC-6/RC-8 7 Drip Cap DC-1 Inside Corner IS-1 6 8 Preformed Valley PV-1 or PV-2 Side Wall Flashing SW-1
9 4 10 11 2 13 9 11 Gable Rake EF-1/GR-2 10 End Wall Flashing EW-1 15 13 Fascia Cover FC-5/FC-7/FC-9 12 Transition Flashing TF-1 Gambrel Flashing GF-1 14 Pipe Boot *See Page 33 for accessories used when installing these trims and flashings. Base Drip BD-1 *Additional and custom trims are available. Please call Techinical support for more information.
Fascia Cover FC-5/FC-7/FC-9 (10’ Lengths) Eave Drip or Eave Flashing Decking Fastener by others FC-5/FC-7/FC-9 Fastener by others CL-4 Item Fascia Size “A” FC-5 2” x 6” 5” FC-7 2” x 8” 7” FC-9 2” x 10” 9” Component Details SM-Rib Cleat CL-4 FC-5 FC-7 FC-9 “A” 1 1/2” 1/2” Open Hem 1/2” 1/2” 1/2” 2 1/2” 8
Eave Drip ED-1 (10’ Lengths) #9 x 1-1/2" Screw Butyl Sealant Tape Inside Closure SM-Rib Panel #30 Felt min.
Eave Flashing EF-3 (10’ Lengths) #9 x 1-1/2" Screw Butyl Sealant Tape Inside Closure SM-Rib Panel #30 Felt min. 1" max.
Preformed Valley PV-1/PV-2 (10’ Lengths) SM-Rib Panel # 30 Felt min. #9 x 1-1/2" Screw 6" min.
End Wall Flashing EW-1 (10’ Lengths) Tube Sealant Fastener by others CF-3 #30 Felt min.
Side Wall Flashing SW-1 (10’ Lengths) SM-Rib Panel Inside Closure SW -1 #9 x 1-1/2" Screw Butyl Sealant Tape SM-Rib Panel #30 Felt min.
Transition Flashing TF-1 (10’ Lengths) SM-Rib Panel Inside Closure Butyl Sealant TF -1 #30 Felt min.
Gambrel Flashing GF-1 (10’ Lengths) #9 x 1-1/2" Screw Inside Closure #30 Felt min.
Gable Rake EF-1 (10’ Lengths) EF-1 #9 x 1-1/2" Screw Butyl Sealant Tape #30 Felt min.
Gable Rake GR-2 (10’ Lengths) #30 Felt min.
High Side Eave HS-2 (10’ Lengths) HS -2 #9 x 1-1/2" Screw SM-Rib Panel # 30 Felt min.
Hip Cap RC-2 (10’ Lengths) RC -2 Option 1 #30 Felt min. #9 x 2-1/2" Screw Universal Closure 1 1/2" Max. SM-Rib Panel Decking Butyl Sealant RC -2 Option 2 #30 Felt min. 6" Hip Seal Tape #9 x 2-1/2" Screw 1 1/2" Max.
Hip Cap RC-6 Option 1 (10’ Lengths) RC -6 6” Hip Seal Tape SM-Rib Panel #9 x 1-1/2" Screw 1 1/2" # 30 Felt min. Max. Decking RC -6 Option 2 SM-Rib Panel #9 x 1-1/2" Screw Universal Closure 1 1/2" # 30 Felt min. Max.
Ridge Cap RC-8 (10’ Lengths) RC -8 SM-Rib Panel #9 x 1-1/2" Screw Outside Closure 1 1/2" # 30 Felt min. Max.
Vented Ridge with Venturi Vent RC -8 Venturi Vent JC -6 #9 x 2-1/2" Screw Outside Closure SM-RIB Panel 3" min. #30 Felt min.
Vented Ridge with Miami Dade Profile Vent RC -8 # 30 Felt min. SM-Rib Panel #9 x 1-1/2" Screw Profile Vent Decking 3" min.
Pipe Boot Ventilation Pipe Silicone Sealant Around Cut of Boot (optional) Pipe Boot 1-1/2" Screws Spaced 1" Around Base of Pipe Boot Note: Butyl sealant tape under base of Pipe Boot Component Details SM-Rib Pipe Boot Standard Pipe Boot Zipper Pipe Boot 24 Flashing Pipe Boot
Base Drip BD-1 (10’ Lengths) SM-Rib Panel Inside Closure #9 x 1-1/2" Screw BD-1 Component Details BD-1 1 15/16" 7/8" 1 1/4" 25 SM-Rib 1/2"
Double Angle DA-1 (10’ Lengths) SM-Rib Panel Inside Closure #9 x 1-1/2" Screw DA-1 Outside Closure SM-Rib Panel Component Details DA-1 1 15/16" SM-Rib 3/4" 1 1/4" 1/2" 26
Drip Cap DC-1 (10’ Lengths) SM-Rib Panel Outside Closure #9 x 1-1/2" Screw DC -1 Door or Window Component Details DC-1 2 9/16" 5/8" 45° 1/2" 27 SM-Rib 7/8"
Track Cover TC-1 (10’ Lengths) SM-Rib Panel #9 x 1-1/2" Screw Inside Closure TC-1 Component Details TC-1 4 1/8" 2 1/2" 165° SM-Rib 1 5/8" 135° 5" 1/2" 28
J Channel JC-6 (10’ Lengths) #30 Felt min.
Outside Corner GR-2 (10’ Lengths) SM-Rib Panel #9 x 1-1/2" Screw GR -2 Butyl Sealant Tape Component Details GR-2 4 11/16" 1 1/16" 3/8" SM-Rib 4 11/16" 3/4" 30 1 1/16"
Inside Corner IS-1 (10’ Lengths) SM-Rib Panel IS-1 #9 x 1-1/2" Screw Butyl Sealant Tape SM-Rib Panel Component Details IS-1 1/2" 5/8" 1 5/8" 4 1/8" 5/8" 1 5/8" 1/2" 31 SM-Rib 4 1/8"
Fastener Guide Fastener Size Finish Application #9 - 1 1/2” Painted #9 - 1 1/2” Mill Finish Fastening galvanized based panels or trims to a wood substrate #9 - 2 1/2” Painted #9 - 2 1/2” Mill Finish #9 - 1 1/2” Painted #9 - 1 1/2” Mill Finish #9 - 2 1/2” Painted #9 - 2 1/2” Mill Finish #12 14 x 1” Painted #12 14 x 1” Mill Finish #12 - 3/4” Painted #12 - 3/4” Mill Finish Woodscrew Woodscrew Woodscrew Woodscrew Metal Screw SM-Rib Stitch Screw 32 Fastening galvanized based
Sealants and Accessories PAINT Hip Sealant Tape Butyl Sealant Tape Venturi Vent Miami Dade Profile Vent Outside Closure Strip 33 Touch Up Paint Clear Panels - 12’ Lengths Universal Closure Strip SM-Rib Inside Closure Strip Tube Sealant
Helpful Formulas Rise and Run Multiply Flat Area by Roof Calculator LF of Hips or Valleys per LF of Common Run Height = 1/2 Span x Rise/Run (common run) Height = Span x Pitch Slope = Common Run x Factor Decimal Fraction of a Foot Inch Fraction 2 in 12 1.041 1.424 1” .083 3 in 12 1.031 1.436 2” .167 4 in 12 1.054 1.453 3” .250 5 in 12 1.083 1.474 4” .333 6 in 12 1.118 1.500 5” .417 7 in 12 1.158 1.530 6” .500 8 in 12 1.202 1.564 7” .583 9 in 12 1.250 1.600 8” .
Flashing Angle Specifier Chart * 1:12 2:12 3:12 4:12 5:12 6:12 7:12 8:12 9:12 10:12 11:12 12:12 Ridge Cap 135° 170° 161° 152° 143° 135° 127° 120° 113° 106° 100° 95° 90° Hip Cap 148° 173° 166° 160° 154° 148° 143° 138° 133° 130° 126° 123° 120° Pre-formed Valley 136° 172° 162° 152° 144° 136° 128° 120° 114° 108° 104° 98° 90° High Side Ridge 67° 87° 81° 76° 71° 67° 63° 60° 56° 53° 50° 47° 45° Eave Flashing 90° 94° 99° 104° 108° 112° 116°