TDS

VHI Training Manual DeepSeal-Tech Data VanHearron.com 479-255-6101
DeepSeal Technical Information
CHEMICAL HARDENER, DENSIFIER, SOLUBLE CHLORIDE REDUCER
BENEFITS
Blocks and reduces vapor emissions through concrete but leaves concrete breathable
Purges soluble chlorides and prevents re-entry. Cures and chemically hardens in one application
Does not alter bond ability of concrete
Non-combustible. No flammable solvents
Contains a non-acid penetrating agent resists many acids, oils, greases and salts
May be used as a curing and sealing agent that reduces “green concrete” window from 28 days down to an average of 5 days
_________________________________________________________________________________________________
Description:
Deep Seal is a ZERO VOC non-flammable, non-toxic, non-acid sealer
that strengthens and internally waterproofs cementious materials.
WARNINGS: DeepSeal should never be used on tile. CAN ETCH
GLASS. Remove immediately. Do not dilute or alter. Protect from
freezing. Protect vehicles, glass surfaces, plant life, aluminum,
ceramics, glazed tile and wood from overspray. Remove overspray
with soap and/or water immediately. Unprotected areas should be pre-
wet with water and rinsed continuously. Eye protection, gloves and
appropriate clothing should be worn to minimize skin contact.
Usage:
DeepSeal reduces vapor emissions for application of surface coatings
such as polyurea coatings, epoxy coatings, urethane coatings, as well
as carpet, floor tile, sheet vinyl and hardwood flooring materials. In
conditions where salt air and humidity attack the concrete, causing
oxidation of the reinforcing steel, Deep Seal has proved to halt such
corrosion activity. When DeepSeal is applied to concrete exposed to
such conditions, exfoliation or expulsion of the chlorides takes place.
DeepSeal reacts with free alkali in the concrete forming a silica
hydrogel that fills the capillaries within the matrix. This hydrogel
waterproofs and seals the surface and blocks moisture transfer up to
20 lbs and hydrostatic pressure up to 15 psi, after all materials harmful
to the concrete are removed. This process could take up to thirty days
or longer, depending on the chloride and acidic residual concentration
within the capillaries.
NOTE: This sealer may be applied as a cure and seal, as soon as the
concrete bleed water flashes off. When properly installed, application
of this sealer reduces wait time to apply flooring or coatings to an
average of 5 days. ALWAYS check surface for moisture content
before applying coatings, or flooring.
Application:
Shake well. The surface being treated should be pre-dampened
with water, using a very light mist prior to application of the
sealer. Application temperature range 40°-100°F. Surface must be free
from oils, grease, curing agents, coatings, sealers or any other
products that would inhibit the penetration of the sealer.
Horizontal Surfaces: Avoid over-application and puddling on
horizontal surfaces. Excess unreacted Deep Seal will leave white
crystals on concrete. Brush or broom to more porous area.
Vertical Surfaces: Apply from top to bottom to point of refusal. Apply
sealer in two even coats using a low-pressure sprayer. After the first
coat has soaked in, immediately apply the second coat. Apply only as
much material as the surface will readily absorb. Areas that absorb
sealer at faster rate will require additional coats. After the final coat of
sealer is dry, spray a light mist of water over the treated area. After the
first water-mist is dry to touch, apply a second water-mist coat.
Clean Up: Rinse equipment with cold water. Do not leave behind
any empty containers. Dispose of containers appropriately.
Coverage: Rough Slab Finish: 200-250 sq ft/gal
Dense and Smooth Finish: 250-400 sq ft/gal
Compliance: Federal EPA V.O.C.
Disclaimer/Warranties: Neither manufacturer nor seller have any
knowledge or control concerning the purchaser’s use of the product.
No expressed warranty is made by manufacturer or seller with respect
to the results of any use of the product or container that the product
comes in. No implied warranties including, but not limited to, an
implied warranty of merchantability or an implied warranty of fitness for
a particular purpose are made with respect to the product. User shall
rely on his or her own information and tests to be determine suitability
of the product for the intended use and user assumes all risk and
liability resulting from use of the product. Neither manufacturer nor
seller assume any liability for personal injury, loss or damage resulting
from the use of the product. We do not suggest or guarantee that any
hazards listed herein are the only ones which may exist. In event that
the product shall prove defective, buyer’s exclusive remedy shall be
that the seller or manufacturer shall, upon written request of buyer,
replace any quantity of the product which is proven to be defective or
shall, at its option, refund the purchase price of the product upon return
of the product. Manufacturer shall not be responsible for use of this
product in a manner to infringe on any patent held by others.
Different concrete composites (flash additives) may require different system approaches. Call for recommendations.