SDS

Safety Data Sheet
Date of Issue:Feb.22, 2016 File No.: JY-SDS-021901
Page 6 of 14
fractionsynthetic (vacated)
TWA: 2.5 mg/m3 respirable
dust natural (vacated)
TWA: 10 mg/m3 total dust
synthetic (vacated)
TWA: 5 mg/m3 respirable
fraction synthetic
TWA: 15 mppcf natural
Lithium Cobalt oxide
12190-79-3
-
Lithium
hexafluorophosphate
21324-40-3
TWA: 2.5mg/m
3
F
TWA:2.5mg/m
3
dust(vacated)
TWA: 2.5mg/m
3
-
Copper
7440-50-8
TWA: 0.1 mg/m3 fume
TWA: 1 mg/m3 dust and
mist
(vacated) TWA: 0.1 mg/m3
Cu
dust, fume, mist
IDLH: 100 mg/m3 dust,
fume and mist
TWA: 1 mg/m3 dust and
mist
TWA: 0.1 mg/m3 fume
Aluminum
7429-90-5
TWA15mg/m
3
total dust
TWA: 5mg/m
3
respirable fraction
(vacated)
TWA:15mg/m
3
total dust(vacated)
TWA:5mg/m
3
respirable fraction
(vacated)TWA:5mg/m
3
Al
Aluminum
IDLH:10mg/m
3
Total dust
TWA:5mg/m
3
Respirable dust
Nickel
7440-02-0
TWA:1mg/m
3
(vacated)
TWA: 1mg/m
3
IDLH:10mg/m
3
TWA:0.015mg/m
3
ACGIH TLV: American Conference of Governmental Industrial Hygienists-Threshold Limit Value
OSHA PELOccupational Safety and Health Administration-Permissible Exposure Limits
NIOSH IDLH Immediately Dangerous to Life or Health
Other Exposure Guidelines:
Vacated limits revoked by the court of Appeals decision in AFL-CLO v. OSHA, 965F, 2d
962(11th Cir., 1992) See section 15 for national exposure control parameters.
8.2 Appropriate engineering controls
Engineering Measures:
Showers Eyewash stationsVentilation systems
8.3 Individual protection measures, such as personal protective equipment
Respiratory protection : No protective equipment is needed under normal use conditions. If
exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be
required.
Eye /face protection: if splashes are likely to occur: Wear safety glasses with side shields(or
goggles). None required for consumer use.