Installation Guide

Wellmade® Hydri-CoreTM Engineered Vinyl Plank/Tile
Installation Guide
Wellmade Hydri-CoreTM is a High Density Plastic Composite (HDPCTM) flooring with patent pending technology,
Hydri-Core is an engineered vinyl plank/tile flooring that uses no adhesive to bond the vinyl layers together and
features the patented Unilin® click system and is installed as a glueless floating floor. The interlocking planks lock
together to provide a tight water resistant seam, can be installed over most floor surfaces, and is suitable for both
residential and light commercial interior applications. For technical information or questions, you can email:
customersupport@wellmadefloors.com , or call 866.582.0848 (US only); outside the US, call 503.582.0848.
General Information:
1. Flooring should be transported and stored in a neatly stacked fashion on a smooth flat surface. Be sure to
Inspect the run numbers/production dates on the boxes as different runs may be slightly different, once
installed it becomes the installers responsibility.
2. Maintain a constant temperature between 60° and 85°F (18.33° and 29.44°C) before, during, and after
installation.
3. Acclimation is ideal, but not required; flooring should be stored in the areas that it is going to be installed
in for a minimal 24 hours to assure equilibrium.
4. Engineered Vinyl flooring should only be installed after other trades have finished and the jobsite has
been cleaned and cleared of debris that could potentially damage a finished installation.
5. Inspect flooring for damage, defects, or shading issues before installation; claims for visual defects will not
be accepted after cutting and/or installed.
6. Mix and install planks/tiles from several different cartons during installation to ensure a random
appearance.
7. Leave 1/4 inch for expansion around the entire perimeter of the flooring.
8. Flooring should be protected from direct exposure to UV light by using shades or blinds when necessary.
Subfloors:
Hydri-Core flooring can be installed over a variety of subfloor surfaces including concrete on all grade levels, wood
and many other existing hard surface floors. The subfloors must be clean, smooth, flat, solid (no movement), and
dry. Do not install planks over floors that are sloped for drainage. Any uneven areas greater than 1/4 inch
in a 10 foot radius should be leveled with a Portland cement based patching compound. Wellmade Engineered
Vinyl Plank/Tile is impervious to water damage but they do not prevent the transmission of moisture. Care should
be taken to keep moisture from collecting on either side of the flooring to prevent the growth of unhealthy mold
and mildew.
Concrete Subfloors:
Hydri-Core flooring can be installed over concrete on all grade levels; a moisture barrier is recommended but not
required, and should consist of at least a 6 mil polyethylene film with the sheets overlapping 6” and taped to
prevent moisture migrating to the flooring.. Moisture vapor emissions should not exceed 5 lbs./24 hour per 1,000
sq. when tested with the Anhydrous Calcium Chloride Test in accordance with ASTM F 1869 or 85% RH in

Summary of content (6 pages)