More user manuals on ManualsBase.
Table of Contents Introduction...................................................................................................... 3 FCC Statement........................................................................................... 4 IC Statement.............................................................................................. 5 Mounting the BC-RH96.................................................................................. 7 Using the Mounting Bracket..............................
● It recognizes the scanner baud rate for reliable communications between units. ● Its Volume and Squelch controls emulate those on the scanner. ● It provides a large, easy to read LCD display with adjustable backligh and contrast levels. ● It emulates your mobile scanner’s Close Call and Alert LED signals. Please read the entire manual to familiarize yourself with installation and operation for maximum enjoyment.
FCC Statement If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ● Reorient or relocate the receiving antenna. ● Increase the separation between the equipment and the receiver. ● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
IC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. . this device must accept any interference received, including interference that may cause undesired operation. More user manuals on ManualsBase.
● Remote connection cable, 10 feet in length. ● A correctly polarized vehicle DC adapter to let you connect the Remote Head to a convenience outlet in your vehicle that provides 12-13.8 VDC. ● This Owner’s Manual. ● A set of pocket-sized Quick Reference Configuration cards for convenient setup and usage. ● A Self Adhesive Cable Clamp Included with your BC-RH96 Your Bearcat Remote Head is supplied with essential components and accessories to get you operational. Supplied are: ● The BC-RH96 Remote Head unit.
Mounting the BC-RH96 or in front of your dash, armrest console, or other location. If you drill carelessly, expensive damage can result. If in doubt, consult your vehicle dealer’s service department or a qualified professional installer. The following two mounting methods are suggestions used by most. Depending upon your individual situation, you may decide on a different approach. Important: AVOID AIRBAG DEPLOYMENT ZONES.
●- 1. Using the supplied screws or other suitable hardware, secure the bracket. . Insert the BC-RH96 and insert the bracket knobs to lock the Remote Head in position. Under Dash Bracket 3. Attach the provided Cigarette Lighter Power Cord to the rear power jack marked DC IN 13.8V. Then plug the adapter end into a dash mounted 12V DC socket. Star Washers & Screws Bracket Knobs 4. Insert the 3-Conductor Mini-Plug of the supplied ten-foot cable in the REMOTE jack on the back of the scanner.
5. Route the Remote Cable through the Slotted Guide (3) so it lies flat. Route the Power Cord so it does not interfere with any other wires. Follow the directions supplied with the hook and loop material. Locate a suitable spot on the dash, console, or other area. If you use the Remote Head in another place such as a radio room, using tape lets you quickly mount or remove the Head as desired. Using Hook and Loop Material The rear of the unit, when all connectors and cables are properly routed, is flat.
BC-RH96 Connections Note: Connect the Remote Cable and route it through the cable channel as shown. Then connect the DC Power Cable and route it through the channel. 1 DC IN 13.8V REMOTE 2 Always route both cables through the channel. 3 1 DC Power Input Jack 2 To Remote Cable Mini-Plug 3 Cable Routing Guides 4 Data Port (for firmware updates) 4 More user manuals on ManualsBase.
Connecting Cables diameter and wire it with the center positive using at least 18 gauge wire to an extra fuse block terminal of your vehicle. There are three cables that you can connect to the BCRH96. ● The DC power cable ● The Remote Control cable ● The Data Port cable (not supplied with BC-RH96) The Remote Head cannot turn power to the scanner off or on. Therefore, consider connecting the power lead of the scanner to a terminal on your vehicle that is turned off when you turn off the ignition key.
the guides to keep the cable correctly positioned. Then, route the remainder of the cable toward the location of your target scanner. When doing so, be sure to avoid sharp metal edges of your vehicle’s body, or other possible hazards. Be sure the cable does not interfere with controls, operation of the vehicle, or passenger safety. Insert the cable’s special connector in the front port of the BCT15/BCD996T mobile scanner, or the side port of the BR330T/BCD396T handy scanner.
Control Configuration Guides Important: If you have more than one scanner, be sure to turn off power to the BC-RH96 before switching target scanners. The BC-RH96 lets you remotely operate the following scanners: ● BCT15 Mobile Scanner ● BCD996T Mobile Scanner ● BR330T Handy Scanner ● BCD396T Handy Scanner To assist you to better understand each of these changes, a set of pocket-sized Quick Reference Cards are provided. The diagrams on the next pages replicate the card diagrams.
FUNC BR330T F1 F2 pri FUNC wx LIGHT F1= L/O F1 F2 pri wx F3 F3 MENU BCD396T rcl race rev car F2= MENU L/O att LIGHT F1= F3= The BR330T Key Configuration More user manuals on ManualsBase.
BCT15 STATE F1 F2 F3 MENU BCD996T F1 PRI WX F2 SRCH1 SRCH2 SRCH3 FUNC F3 ATT REV ALERT MENU L/O SRCH4 SRCH5 SRCH6 FUNC ATT REV L/O LIGHT MUTE F + LIGHT F1= SRCH1 SRCH2 SRCH3 F2= F1= F3= The BCT15 Key Configuration More user manuals on ManualsBase.
Operation If you have not connected a target scanner, you see the screen below. If the BC-RH96 remains on while you turn on the scanner, this display is automatically replaced with the scanner’s initial display. Apply power to your target scanner and set its Baud Rate to the highest setting. Make sure that the Remote Control cable is properly connected, and rotate the VOL control clockwise past OFF until it clicks.
When you turn the Remote Head off, you see the screen to the right which reminds you that power is still applied to the target scanner. Brightness Auto-Adjust (mobile scanners only) When you connect a mobile scanner, the Remote Head automatically adjusts its backlight brightness level to match the brightness level of the target mobile scanner. If you change the brightness level on either the Remote Head or the target scanner, the level changes on both devices at the same time.
Configuration — Menu Mode ● To exit from the Menu Mode, press [SCAN], [HOLD], or [L/O]. ● To re-enter the Menu Mode, turn the Remote head off then on while holding in [MENU]. Once you have the units on, press [MENU] to enter the Configuration Settings Options. You can skip the opening screens by holding [MENU] while turning on power. You see the Remote 4GOQVG *GCF /GPW Head Menu screen. ● To select an item on the screen, rotate the FUNC knob to scroll to the item. Setting the BC-RH96 LCD Contrast 5GV .
Setting Mobile Options The Default selection associates the F Keys on the Remote Head exactly the same as the corresponding F Key on the target mobile scanner. 1. Scroll to highlight Mobile Option, then press the rotary knob. . The screen shows Set Key Assign. Press the rotary knob again. Mobile Default Key Emulation Mobile Default Key Assigment 3. Scroll to the desired key (F1 Key, F2 Key, or F3 Key) and press the rotary knob to select it.
The Default Option table only applies to the BCT15 and BCD996T. The following list applies to all four scanners (mobile and handy type) for F1, F2, or F3. CC Band Menu.............Close Call Band Setting Menu Settings Menu........................................ Settings Menu Brdcst Scrn Menu..........Broadcast Screen Band Menu Search L/O Menu................................Review L/O List F1, F2, F3 Key Function F+Menu Key....................................[FUNC]+[MENU] F+L/O Key.....................
Setting Handy Options The Default selection associates the F Keys on the Remote Head exactly the same as the corresponding F Key on a Mobile scanner or a function on a Handy scanner. 1. Scroll to highlight Handy Option, then press the rotary knob. Handy Default Key Emulation Default Handy Option Key Assigment . The screen shows Set Key Assign . Press the rotary knob again. ORIGINAL Key Operation BR330T BCD396T [F1] Custom Search [F ] CC Only [F3] Tone-Out Key 3.
The five settings are: Off: Function mode is continuously enabled only while pressing the Control or SQ knob. Setting the Function Mode If you scroll to the Handy Option menu, you can highlight Set Func Mode. Select this to choose between Set Hold Timer and Set Auto Release. Setting Hold Timer When you select this option, you can scroll through and select from five settings. The setting determines how long the knob acting as the FUNC control is enabled each time you press it if you do nothing else.
Setting Auto Release Miscellaneous Choose this option to set the Function Auto Release to On or Off. Volume Settings - For Handy Scanner While it is possible to configure the BC-RH96 rotary FUNC control as your VOL control, we suggest not doing so. The VOL control still functions as a volume control. If the FUNC control is configured as volume, it is possible to have a situation that a very slight movement of the VOL control results in a sudden and loud increase in your audio.
Control Limitations Serial Operation Precautions There are some operations that cannot be performed using the BC-RH96. The BCT15 and the BCD996T have a 9-pin serial connection in the back designed for use with serial operations in addition to the special serial jack on the front. Other than connecting a GPS, the front and the back cannot be used or connected at the same time when the BC-RH96 is in use.
Initialize Memory (Reset) Using the Cable Clamp A self-adhesive clamp/ guide is provided to assist you to safely route the Remote Cable to your target scanner. With the unit off, press and hold the following keys Clean the planned and turn on power at the same time: [2], [9] and location, peel the base [HOLD].You see the reset screen below. covering, and firmly If you turn off power press it on the scanner. during reset, the process Then route the Remote Cable through the guide.
Specifications Size (inches) 7.2 W x 1.9 D x 2.2 H (without knobs) Weight (Remote Head only) 0.7 pounds Input Voltage 13.8 Vdc (11.0 - 16.6 Vdc) Current Drain (nominal) In standby: 2 mA In use: 106 mA (backlight high) Operating Temperature -20° to +60° C (-4° to +140° F) More user manuals on ManualsBase.com One Year Limited Warranty Important: Evidence of original purchase is required for warranty service.
equipment or parts or as part of any system not manufactured by Uniden, or (F) installed or programmed by anyone other than as detailed by the owner’s manual for this product.