Front Panel 14Apollo x16 Hardware Manual
(11) Monitor Function Switch (FCN)
This is an assignable switch that can be configured to control one of three monitoring
functions. The function of the switch is configured with the FCN SWITCH ASSIGN menu
in the Hardware panel within the Console Settings window. Refer to the Apollo Software
Manual for details.
The amber LED within the switch flashes when the monitoring function is active. The
function is toggled with the switch is pressed again. The available functions are:
ALT 2 – Selects the ALT 2 monitor speakers. The monitor signals are routed to
outputs 3 & 4 instead of the main monitor outputs, and the Monitor Level Indicator
ring (#13) is amber instead of green when ALT 2 is active.
MONO – Sums the left and right channels of the stereo monitor mix into a
monophonic signal. The Monitor Level Indicator ring (#13) flashes when MONO is
active.
DIM – Attenuates the signal level at the monitor outputs by the dB amount set in the
CONTROL ROOM strip within the Console application. The Monitor Level Indicator
ring (#13) flashes when DIM is active.
TALKBACK – Activates the talkback mic and the DIM function. Talkback is active
when the button is lit. Press and release the button quickly to latch talkback ON. To
momentarily activate the function and deactivate when the button is released, press
for longer than 0.5 seconds. The Monitor Level Indicator ring (#13) flashes when
talkback is active.
Note: When more than one Apollo interface is connected in a multi-unit
configuration, the FCN switch is operable on the designated monitor unit only.
(12) Monitor Level & Mute Knob
This rotary encoder serves two functions. Rotating the knob adjusts the monitor output
level, and pressing the knob mutes the monitor outputs.
Monitor Level
Rotating the knob clockwise increases the signal level at the Left & Right Monitor
Outputs on the rear panel. If ALT monitor outputs are configured and active, this knob
controls the signal level at the ALT monitoring line outputs.
Monitor Mute
Pressing the Monitor knob toggles the mute state of the signals at the Left & Right
Monitor Outputs on the rear panel. If ALT monitoring is configured in the Hardware panel
within the Console Settings window (when ALT COUNT is a non-zero value), the ALT
monitor outputs are also muted by this control.
When the monitor outs are muted, the Monitor Level Indicator ring (#13) is red.