Owner manual
Table Of Contents
- Welcome To Your THZ-100 Thermostat
- Installing Your THZ-100 Thermostat
- Wiring Your THZ-100 Thermostat
- Definitions
- Single Stage Furnace and Single Stage A/C
- Dual Stage Furnace and Dual Stage A/C
- Single Stage Heat Pump with Reversing Valve O
- Single Stage Heat Pump with Reversing Valve B
- Dual Stage Heat Pump with Reversing Valve O
- Dual Stage Heat Pump with Reversing Valve B
- Boiler and A/C with Separate Transformers
- First Stage Radiant Floor Heat, Second Stage Furnace with Single Stage Cooling and External Pilot Duty Relay
- Operation For Your THZ-100 Thermostat
- Thermostat Display Information
- Changing the Heating Temperature (Temperature Override)
- Changing the Cooling Temperature (Temperature Override)
- Auxiliary Heat
- Emergency Heat
- Password Protection
- Programs
- Options
- Climate Modes
- Changing the Fan Modes
- Accessing Temperature Sensor Information
- Turning Emergency Heat On or Off
- Changing the Auxiliary Heat Offset Temperature
- Changing the 2nd Stage Offset Temperature
- Resetting the Filter Reminder
- Turning the Password Protect Feature On or Off
- Changing the LCD Screen Options
- Viewing THZ-100 Thermostat Information
- Setting the Date and Time
- Discovery Mode
- Troubleshooting Thermostat On-Screen Notifications
- Resetting the THZ-100 hermostat
Page 27
THZ-100 THERMOSTAT
If the Fan Modes screen times out and goes back to the main screen
without pressing the OK button, no change is made to the fan
mode.
In On mode the fan operates continuously regardless of the
equipment operation.
Selecting the Fan to Cycle Periodically
If you desire the system fan to cycle on and off periodically then use
the arrow keys to move the highlight bar to Cycle.
Press the key below the OK key label in the smart-key label at the
bottom right of the display to select this new mode. If you decide
to cancel the operation then press the key below the Cancel key
label in the smart-key label at the bottom left of the display.
If the Fan Modes screen times out and goes back to the main screen
without pressing the OK button, no change is made to the fan
mode.
In Cycle mode, the fan cycles on for 10 minutes then off for 10
minutes. If the system turns on for a heating or cooling cycle then
the fan stays on for that complete cycle then turns off for 10 minutes
and back on for 10 minutes until the next cooling or heating cycle.
Selecting the Fan On Only with HVAC Equipment
If you desire the system fan to turn on only when the HVAC system
equipment is on then use the arrow keys to move the highlight bar
to Auto.
Press the key below the OK key label in the smart-key label at the
bottom right of the display to select this new mode. If you decide
to cancel the operation then press the key below the Cancel key
label in the smart-key label at the bottom left of the display.
If the Fan Modes screen times out and goes back to the main screen
without pressing the OK button, no change is made to the fan
mode.
In Auto mode, the fan turns on any time the heating or cooling
system cycles on and turns off when the system turns off and has
gone through any required cool down time.