Manual

General instructions:
Gas specifications
GAS
Univex gas ovens are equipped with a 3/4" NPT gas connection located at the
front left or front right (depending on the model) of the oven. Have a licensed gas
installer make the connection and test all fittings and pipe connections for leaks.
Use approved gas leak detectors (Soap solutions or equivalent) over and around the
fittings and pipe connections. DO NOT USE A FLAME TO TEST FOR LEAKS.
Eurosit is the gas control valve that operates the interior radiant burner. Eurosit is
located under the oven to the front left or on the front right depending on the model.
Only qualified personnel must start the appliance.
The nominal thermal capacity must be verified by an authorised technician, according
to the information given in this operation manual. This check is necessary when
changing oven or adapting to a different type of gas and also each time the appliance
is serviced. Both the nominal thermal capacity and connection pressures are given in
the technical data table. Never tamper with the sealed components.
4