Instruction manual

7510/7512
WIRING DIAGRAM
MODEL 7510 - 7512
100V, 50/60HZ, 1PH
FIGURE 11B
* CAUTION: Installations with 50HZ electrical supplies should have black motor lead connected to
110V output terminal ONLY. Connection to higher voltage outputs could cause motor failure. The
transformer has been wired at the factory for 50HZ operation at 110V output. If you have 60HZ
electrical supply the black motor lead can be switched to 115V output terminal for optimal slicer
performance.
* * The black motor lead should ONLY be connected to 120V output when the supply voltage is
consistently at 90V or less (50 or 60HZ).
IMPORTANT
Before making electrical connections, check the specifications on the data plate to assure they agree
with those of your electrical service
Whenever cleaning or maintenance is being performed DISCONNECT electrical cord.
PAGE 29