Manual

Operation manual
Pag. 14/15
MACISTE LIFTER
6. Clearing and maintenance
6.1. Machine cleaning
Always keep the machine clean to prevent the formation of micro-organism colonies that can alter
the end product and be harmful to health. It is also important that flour does not deposit on moving
parts, thus creating annoying squeaks and abnormal wear.
Cleaning: the machine is not spray-proof; it must not be cleaned with running water or compressed
air, to minimize dust movement. To vacuum the dust, use a professional vacuum equipped with
adequate filters depending on the grain size of the flour.
INTERVAL
METHOD
g
F, M
6.2. Machine lock-up and necessary solutions
Operating anomalies
Possible causes
Repairs
Performed by
Turning the master switch
into position 1, the
indicator light does not
come on.
Plug not inserted properly,
or its wires are detached
Check the connection
Personnel authorised by
the employer and/or
qualified personnel in
possession of the
technical knowledge of
the work.
Pressing the START
button, the machine does
not start.
The mobile guards are not
closed properly.
Restore the correct
position of the guards
Personnel authorised by
the employer and/or
qualified personnel in
possession of the
technical knowledge of
the work.
Difficulties in lifting
Check the presence of oil
in the hydraulic unit
Use Agip OSO46
hydraulic oil or equivalent
oil.
Personnel authorised by
the employer and/or
qualified personnel in
possession of the
technical knowledge of
the work.