7. Maintenance and clearing
7.1. Routine maintenance
1) Periodically (six-monthly.) grease the machine through the
specific grease nipples.
2) Use food grease, e.g. BECHEM BELORUB FB19, use a manual
coupling grease pump.
3) For PPE wear shoes with reinforced tip and non-
slip sole,
helmet and goggles.
4) Carefully read the lubricant's technical data sheet and follow its
instructions.
Need to provide adequate training to maintenance personnel.
7.2. Machine lock-up and necessary solutions
Operating anomalies
Possible causes
Repairs
Performed by
Turning the master switch
into position 1, the
indicator light does not
come on.
Plug not inserted
properly, or its wires
are detached
Check the connection
Personnel authorised by the
employer and/or qualified
personnel in possession of the
technical knowledge of the
work.
Pressing the START
button, the machine does
not start.
1) The protection
grid is open.
2) Safety micro
switches anomalies.
1) Rotate it and reposition it
in closed position.
2) Replace the micro
switch.
Personnel authorised by the
employer and/or qualified
personnel in possession of the
technical knowledge of the
work.
The spiral does not rotate
smoothly.
1) Loose chain or
belt.
2) Worn belt.
1) Tension the chain or belt.
2) Replace the belt.
Personnel authorised by the
employer and/or qualified
personnel in possession of the
technical knowledge of the
work.
The bowl does not rotate
smoothly.
1) Loose chain.
2) Worn chain.
1) Tension the chain.
2) Replace the chain.
Personnel authorised by the
employer and/or qualified
personnel in possession of the
technical knowledge of the
work.
The tool does not revolve
normally on the tool
carrier shaft.
1) Loose chain or
belt.
2) Worn belt.
1) Tension the chain or belt.
2) Replace the belt.
Personnel authorised by the
employer and/or qualified
personnel in possession of the
technical knowledge of the