Product data

USRobotics
Command Reference
Fax Class 1 and Fax Class 1.0 Commands - 116
OK If the modem's transmit buffer becomes empty and the last
transmitted character is was not NUL, the modem will turn off the
transmit carrier, return to the command state, and report the OK
result code.
Reporting Current or Selected Values
Command: +FTM?
Response: +FTM: <mod>
Example: +FTM: 98 For V.17 9600 bps.
Reporting Supported Range of Parameter Values
Command: +FTM=?
Response: +FTM: (<mod> range)
Example: +FTM: 3,24,48,72,73,74,96,97,98,121,122,145,146
+FRM - Receive Facsimile
This command causes the modem to enter the receiver mode using the
modulation defined below.
Syntax
+FRM=<mod>
Defined Values
<mod> Decimal number corresponding to the selected modulation mode
and data rates shown in Table 4-2.
Reporting Current or Selected Values
Command: +FRM?
Response: +FRM: <mod>
Example: +FRM: 98 For V.17 9600 bps.
Reporting Supported Range of Parameter Values
Command: +FRM=?
Response: +FRM: (<mod> range)
Example: +FRM: 3,24,48,72,73,74,96,97,98,121,122,145,146
Result Codes
CONNECT Reported when the selected carrier is detected.