S-Parameter Summary
AT=x - Write to Selected S-Parameter
This command writes the value x to the currently selected S-Parameter. An S-
Parameter can be selected by using the ATSn command. All of the S-Parameters
will return the OK response if x is a number. Some registers may not be written
due to country specific PTT limitations.
Syntax
S=x
Table 4-1: S-Parameter Summary
Register Function Units
S0 Number of Rings to Automatic Answer rings
S1 Ring Counter rings
S2 Escape Character ASCII
S3 Line Termination Character ASCII
S4 Response Formatting Character ASCII
S5 Command Line Editing Character ASCII
S6 Wait Time for Dial Tone Before Blind Dialing, or After "W" Dial Modifier s
S7 Wait Time For Carrier After Dial, For Silence, or For Dial Tone After "W"
Dial Modifier
s
S8 Pause Time for Dial Delay Modifier s
S10 Carrier Loss Disconnect Time 0.1 s
S11 DTMF Tone Duration 0.001 s
S12 Escape Prompt Delay 0.02 s
S18 Test Timer s
S28 Select Pulse Dial/Make/Break Ratio -
S29 Flash Dial Modifier Time 10 ms
S30 Disconnect Inactivity Timer 10 s
S46 Data Compression Control -