PREPARACIÓN
Artículo HP GPM
Profundidad de bombeo en pies - Capacidad en galones por minuto a 40 PSI (presión por pulgada cuadrada)
20 40 60 80 100 120 140 160 180 200 225 250 275 300 325 350 400 450 500 550 600 650
5 GPM
4H05A05001
1/2 5 8.3 7. 9 7.5 7.1 6.7 6.3 5.9 5.4 4.9 4.2 3.5 2.4
4H05A05005
4H05A05301
4H05A05305
4H05A07301
3/4 5 8.7 8.5 8.2 8.0 7.7 7. 5 7.2 6.9 6.5 6.2 5.7 5.3 4.9 4.4 3.1
4H05A07305
4H05A10301
1 5 8.7 8.5 8.3 8.1 7.9 7. 7 7.5 7.2 6.9 6.7 6.3 6.0 5.4 4.6 3.7 2.5 2.4
4H05A10305
4H05A15301 1-1/2 5 9.0 8.8 8.7 8.5 8.4 8.2 8.0 7. 8 7.6 7. 4 7.2 6.8 6.3 5.9 5.1 4.6 4.1
7 GPM
4H07G05005
1/2 7 11.3 10.7 10.0 9.3 8.5 7. 7 6.8 5.7 4.4 2.84H07G05301
4H07G05305
10 GPM
4H10A05001
1/2 10 12.8 12.0 11.0 10.0 8.7 6.9 4.8
4H10A05005
4H10A05301
4H10A05305
4H10A07301
3/4 10 14.3 13.8 13.3 12.8 12.4 11.4 11. 0 10.5 9.6 8.9 7.9 6.1 3.5
4H10A07305
4H10A10301
1 10 14.9 14.5 14.1 13.7 13.3 12.9 12.4 11.9 11.4 10.9 10.3 9.5 8.6 7. 9 6.5 4.5
4H10A10305
4H10A15301
1-1/2 10 15.3 15.0 14.8 14.5 14.2 13.9 13.6 13.4 13.0 12.7 12.4 11.9 11.5 11.0 10.5 10.0 8.6 7.1 4.4
4H10A15305
4H10A20301 2 10 14.9 14.6 14.4 14.2 14.0 13.8 13.4 13.1 12.8 12.6 11.9 11. 2 10.5 9.6
4H10G05001
1/2 10 12.8 12.0 11.0 10.0 8.7 6.9 4.8
4H10G05005
4H10G05301
4H10G05305
4H10G07301
3/4 10 14.3 13.8 13.3 12.8 12.4 11.4 11. 0 10.5 9.6 8.9 7.9 6.1 3.5
4H10G07305
4H10G10301
1 10 14.9 14.5 14.1 13.7 13.3 12.9 12.4 11.9 11.4 10.9 10.3 9.5 8.6 7. 9 6.5 4.5
4H10G10305
19 GPM
4H19A05001
1/2 19 13.0 12.2 3.5
4H19A05305
4H19A07301
3/4 19 20.6 18.7 16.6 14.3 11.0 5.5
4H19A07305
4H19A10301
1 19 22.5 21.2 19.8 18.4 16.8 15.2 12.8 10.4 5.6
4H19A10305
4H19A15301
1-1/2 19 24.2 23.3 22.4 21.4 20.5 19.5 18.5 17.4 16.3 14.9 12.7 9.7 5.7
4H19A15305
4H19A20301 2 19 25.3 24.6 24.1 23.5 22.8 22.2 21.5 20.8 20.1 19.3 18.3 17.2 15.9 14.6 12.9 11.0 5.3
4H19A30301 3 19 25.8 25.4 25.0 24.5 24.1 23.6 23.2 22.7 22.2 21.7 21.0 20.3 19.8 19.0 18.2 16.6 14.7 12.2 9.2
4H19G10301
1 19 22.5 21.2 19.8 18.4 16.8 15.2 12.8 10.4 5.6
4H19G10305
NOTA: La capacidad de bombeo en galones por minuto (GPM) debe ser igual a la cantidad de juegos de grifería en el hogar. Si tiene 3 juegos de
grifería x 2 baños, más 3 juegos en la cocina y 1 juego en el exterior de la casa, en total tiene 10 juegos de grifería. Según el cuadro anterior, la bomba
debe suministrar 10 GPM. Los hogares típicos con 3 o 4 habitaciones requieren entre 8 y 12 GPM.
Cuadro A de rendimiento de la bomba
4H05A05001 127185 SUB/4 5GPM CI 15STG
4H05A05005 not required SUB/4 5GPM CI 15STG
4H05A05301 127189 SUB/4 5GPM CI 15STG
4H05A05305 not required SUB/4 5GPM CI 15STG
4H05A07301 127197 SUB/4 5GPM CI 21STG
4H05A07305 not required SUB/4 5GPM CI 21STG
4H05A10301 126319 SUB/4 5GPM CI 26STG
4H05A10305 not required SUB/4 5GPM CI 26STG
4H05A15301 133589 SUB/4 5GPM CI 35STG
4H07G05005 not required SUB/4 7GPM CI 10STG
4H07G05301 127189 SUB/4 7GPM CI 10STG
4H07G05305 not required SUB/4 7GPM CI 10STG
4H10A05001 127185 SUB/4 10GPM CI 8STG
4H10A05005 not required SUB/4 10GPM CI 8STG
4H10A05301 127189 SUB/4 10GPM CI 8STG
4H10A05305 not required SUB/4 10GPM CI 8STG
4H10A07301 127197 SUB/4 10GPM CI 12STG
4H10A07305 not required SUB/4 10GPM CI 12STG
4H10A10301 126319 SUB/4 10GPM CI 15STG
4H10A10305 not required SUB/4 10GPM CI 15STG
4H10A15301 133589 SUB/4 10GPM CI 20STG
4H10A15305 not required SUB/4 10GPM CI 20STG
4H10A20301 137224 SUB/4 10GPM CI 26STG
4H10G05001 127185 SUB/4 10GPM CI 8STG
4H10G05005 not required SUB/4 10GPM CI 8STG
4H10G05301 127189 SUB/4 10GPM CI 8STG
4H10G05305 not required SUB/4 10GPM CI 8STG
4H10G07301 127197 SUB/4 10GPM CI 12STG
4H10G07305 not required SUB/4 10GPM CI 12STG
4H10G10301 126319 SUB/4 10GPM CI 15STG
4H10G10305 not required SUB/4 10GPM CI 15STG
4H19A05001 127185 SUB/4 19GPM CI 5STG
4H19A05305 not required SUB/4 19GPM CI 5STG
4H19A07301 127197 SUB/4 19GPM CI 7STG
4H19A07305 not required SUB/4 19GPM CI 7STG
4H19A10301 126319 SUB/4 19GPM CI 9STG
4H19A10305 not required SUB/4 19GPM CI 9STG
4H19A15301 133589 SUB/4 19GPM CI 12STG
4H19A15305 not required SUB/4 19GPM CI 12STG
4H19A20301 137224 SUB/4 19GPM CI 16STG
4H19A30301 136800 SUB/4 19GPM CI 22STG
4H19G10301 126319 SUB/4 19GPM CI 9STG
4H19G10305 not required SUB/4 19GPM CI 9STG
Cuadro B de la caja de control - Bombas de 3 cables más puesta a tierra
Modelo de la
bomba
Modelo de
la caja de
control
Descripción de la bomba
Modelo de la
bomba
Modelo de
la caja de
control
Descripción de la bomba
ADVERTENCIA: BOMBAS SUMERGIBLES DE TRES CONDUCTORES SOLAMENTE. Esta bomba
sumergible deberá cablearse directamente a una caja de control Franklin que tenga la
misma clasificación de caballaje y voltaje, para que funcione adecuadamente. DEBE USARSE
CON UN A CAJA DE CONTROL.
PREPARACIÓN