Operating Guide

12
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING.
TROUBLESHOOTING
Symptom Possible Causes Corrective Action
Vacuum will not operate
1) No power supply.
1) Check power supply cord,
breakers, fuses.
2) Faulty power cord.
2) Unplug and check the power
cord. If damaged, have it
repaired by a professional.
3) Collection tank full. 3) Empty collection tank.
Dust comes out from motor
cover.
1) The cartridge lter is missing
or damaged.
1) Attach or replace cartridge
lter.
Reduced efficiency and motor/
speed vibration.
1) There is a blockage in the
nozzle, hose, or the collection
tank inlet. The cartridge lter is
clogged by ne dust.
1) Check nozzle, hose and
collection tank inlets for
blockage. Take off the filter
and clean it or install a new
cartridge lter.
Installing Foam Wet Filter
1. Verify that the power cord is disconnected from the outlet. (Fig.1)
2. Remove power head and place in upside down position. Follow instructions to remove
cartridge lter.
3. Carefully slide foam wet lter down over the lter cage making sure the cage is completely
covered. (Fig. 2 & 3)
4. Place the power head onto the collection tank.
Cleaning Foam Wet Filter
1. With the removed power head in an upside down position, carefully remove foam wet lter. (Fig.
4)
2. Use a mild soap and water solution to wash foam wet lter and rinse with clean water. (Fig. 5)
3. Allow lter to air dry before installing and using again.
INSTALLING & CLEANING FOAM WET FILTER
2 3 4
5
1