Operator`s manual

11
WARNING:TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE TROUBLESHOOTING.
Symptom Possible Causes Corrective Action
Vacuum will not operate 1) No power supply. 1) Check power supply – cord,
breakers, fuses.
2) Faulty power cord. 2) Unplug and check the power
cord. If damaged, have it repaired
by a professional.
3) Collection tank full. 3) Empty collection tank.
Dust comes from motor cover. 1) The reusable cloth filter is missing or
damaged.
1) Attach or replace the reusable
cloth filter.
Reduced efficiency and
motor/speed vibration.
1) There is a blockage in the nozzle,
hose, or the vacuum inlets. Or the dust
filter is blocked by fine dust.
1) Check nozzle, hose and inlets
for blockage. Take off the filter and
clean it. Or install new filter.
TROUBLESHOOTING