Warranty

1 2
W A R N I N G : T O R E D U C E T H E R I S K O F E L E C T R I C S H O C K , U N P L U G B E F O R E
T R O U B L E S H O O T I N G .
TROUBLESHOOTING
S y m p t o m P o s s i b l e C a u s e s C o r r e c t i v e A c t i o n
Vacuum will not operate
1) No power supply.
1) Check power supply cord,
b reakers, fuses.
2) Faulty power cord.
2) Unplug and check the power
cord. I f damaged, hav e it
rep aired b y a p rofessional.
3) Collection tank full. 3) Empty collection tank.
Dust comes out from motor
cove r.
1) The cartridge lter is missing
or damaged.
1) Attach or replace cartridge
lter.
Reduced efficiency and motor/
sp eed vi b ration.
1) There is a blockage in the
nozzle, hose, or the collection
tank inlet. The cartridge lter is
clogged by ne dust.
1) Check nozzle, hose and
collection tank inlets for
b lockage. Take off the filter
and clean it or install a new
cartridge lter.
I n s t a l l i n g F o a m W e t F i l t e r
1. Verify that the power cord is disconnected from the outlet. (Fig.1)
2. Remove power head and place in upside down position. Follow instructions to remove
cartridge lter.
3. Carefully slide foam wet lter down over the lter cage making sure the cage is completely
covered. (Fig. 2 & 3)
4. Place the power head onto the collection tank.
C l e a n i n g F o a m W e t F i l t e r
1. With the removed power head in an upside down position, carefully remove foam wet lter. (Fig.
4)
2. Use a mild soap and water solution to wash foam wet lter and rinse with clean water. (Fig. 5)
3. Allow lter to air dry before installing and using again.
INSTALLING & CLEANING FOAM WET FILTER
2 3 4
5
1