Product Manual B
16
TROUBLESHOOTING
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK - UNPLUG BEFORE
TROUBLESHOOTING.
Symptom Possible Causes Corrective Action
Vacuum will not operate
1) No power supply. 1) Check power supply – cord,
breakers, fuses.
2) Faulty power cord.
2) Unplug and check the
power cord. If damaged,
have it repaired by a
professional.
3) Container full. 3) Empty container.
4) Switch in the wrong
position
4) Press the ON ‘I’ button on
the power head.
1) The cartridge lter is
missing or damaged.
1) Attach or replace cartridge
lter.
2) Vacuum has been used to
collect ne dust, such as
drywall dust, replace soot,
or ash, without a ne dust
lter equipped.
2) Remove the standard
cartridge lter and install
the appropriate ne dust
cartridge lter.
1) There is a blockage in the
nozzle, hose, or the
container inlet.
The cartridge lter is
clogged by ne dust.
1) Check nozzle, hose and
container inlets for blockage.
Take off the lter and clean
it.
Or install new cartridge lter.
1) Remote is not paired with
the vac.
1) Reset the remote using the
instructions on page 15.
2) Battery is dead. 2) Replace the battery.
Dust comes out from
motor cover.
Reduced efciency and
motor/speed vibration.
Remote will not operate
Changes or modications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.