Specifications

HMT 360 Transmitter Unit for HMP 360 Series
Humidity and Temperature Probes
BACK to
Price List
Table of
Contents
BACK to
Catalog
Table of
Contents
-11-
Transmitter Unit
HMT 360
PRICE
Transmitter type
RH+T A
$1,485
RH+T+Td+a+Tw+x D
$1,985
Display on cover
no 1
yes 2
$105
Signal output
1 analog output channel (Ch1) 4... 20 mA 1
2 analog output channels (Ch1 + Ch2) 4... 20 mA 2
$230
LonWorks field bus (no analog outputs) TP78 3
$285
Analog output
No analog output A A
signals for Ch1
RH (0... 100%RH) B B
and Ch2
Temperature (choose range-next section) C C
Td (-40...100°C)
(-40...21F)
HH
a (0...500g/m3)
(0...218.5gr/ft3)
JJ
Tw (0...100°C)
(+32...+212°F)
KK
NOTE:
x (0...500g/kg d.a)
(0...3500gr/lb)
LL
- Choose A for both channels with LonWorks field bus
- Td, a, Tw and x are only available with transmitter type D
Ch1
- If only one analog output has been chosen, choose A for Ch2
Ch2
Analog output
-40...+60°C
(-40...+140°F)
A
range for
-20...+60°C
(-4...+140°F)
B
temperature
0...+60°C
(+32...+140°F)
C
-20...+80°C
(-4...+176°F)
D
-20...+120°C
(-4...+248°F)
E
-40...+80°C
(-40...+176°F)
F
-40...+120°C
(-40...+248°F)
G
0...+100°C
(+32...+ 212°F)
H
-20...+180°C
(-4...+356°F)
J
-40...+180 °C
(-40...+356°F)
K
0...+180 °C
(+32...+356°F)
L
Other ( specify ) X
Output units
metric 1
non-metric 2
Cable bushings
cable gland Pg11 A
conduit fitting NPT1/2" (for wire conduits) B
Ex certification an
d
CENELEC 76/117/EEC (VTT) 1
Operating manua
l
no manual A
english B
TOTAL
RH = Relative Humidit
y
a = Absolute Humidity g/m 3
QTY
T = temperature x = Mixing Ratio g/Kg
TOTAL VALUE
Td = Dewpoint Temperature Tw = Wet Bulb Temperature
Sections in italic are available at extra cost.
Sections in bold text are included in the purchase price.
Example of order code with typical settings:
HMT 360 A
1 2BCA1A1B
Transmitter unit
BACK to
Tech Data
Sheet