Specifications

100 Commerce Way, Woburn, MA 01801
TEL: 1-888-VAISALA (824-7252) FAX: (781) 933-8029
E-MAIL: incsales@vaisala.com Access catalog on-line at: www.vaisala.com/inc/ssdcat
46
-10 100
40
50
20
60
30
•C
•C
0.5
0.4
0.3
0.2
0.1
0
-0.1
-0.2
-0.3
-0.4
-0.5
-10
0.8
0.6
0.4
0.2
0
-0.2
-0.4
-0.6
-0.8
•C
0-20 10 20 30 40 50 60 70 80 •C
-20 200
2.0
1.5
1.0
0.5
0
-0.5
-1.0
-1.5
-2.0
40 60 •C10-10 30 50
%RH
70 80
10 4020 605030 8070 %RH
%RH
3
2
1
0
-1
-2
-3
0 90 100
60 Series: 2-wire, 4 to 20 mA output
wall mount RH only HMW60U
RH & T HMW60Y
duct mount RH only HMD60U
RH&T HMD60Y
70 Series: 3-wire, variable voltage output
wall mount RH only HMW70U
RH & T HMW70Y
duct mount RH only HMD70U
RH & T HMD70Y
Relative Humidity (duct-mount models)
Measurement range 0...100 %RH*
Accuracy at +68°F (+20
0
C)
10 4020 605030 8070 %RH
%RH
3
2
1
0
-1
-2
-3
0 90 100
Relative Humidity (wall-mount models)
Measurement range 0...95 %RH*
Accuracy at +68°F (+20 °C)
Temperature dependence
Response time at +68°F (+20 °C),
90% response 15 s (with membrane filter)
Sensor HUMICAP
®
180
* Output signal corresponds to 0-100%RH
General - 60 series
Supply voltage 10...35 VDC (R
L
= 0 ohm)
20...35 VDC (R
L
= 500 ohm)
Output signal 4...20 mA
General - 70 Series
Supply voltage range depends on the selected output signal
DC AC
0...1V 10...35 V 9...24 V
0...5 V 14...35 V 12...24 V
0...10 V 19...35 V 16...24 V
0...20 mA (R
L
= 0 ohm) 10...35 V 11...24 V**
0...20 mA (R
L
= 500 ohm) 20...35 V 17...24 V**
** HMD models only.
General
Operating temperature range
electronics +23...+131°F (-5...+55 °C)
sensor head (duct mount) -4...+176°F (-20..+80 °C)
Storage temperature range -40...+176°F (-40...+80 °C)
Housing
sensor head (duct mount) stainless steel
electronics (duct mount) cast aluminum
electronics (wall mount) ABS plastic
Connections screw terminals 0.5...1.5 mm
2
Sensor protection (duct mount)
standard membrane filter (17039 HM)
option stainless steel
sintered filter (HM46670)
Temperature (Y-models only)
Linearity better than 0.18°F (0.1 °C)
Sensor PT 1000 IEC 751 class B
(HMD 60Y and HMD 70Y)
Measurement range -4...+176 °F (-20...+80 °C)
Accuracy
TECHNICAL DATA - HMD/W 60 AND 70 SERIES
(HMW 60Y and HMW 70Y)
Measurement range +23...131°F (-5...+55 °C)
Accuracy
Meets EMC standard EN50081-1 and EN50082-1.
Specifications subject to change without notice.
HUMICAP is a registered trademark of Vaisala.
BACK to
Table of
Contents
To INDEX
Price Lists:
Duct/Wall
Temp Only