User`s guide

User's Guide ______________________________________________________________________
44 __________________________________________________________________ M210455EN-B
Main
MAWS1 Main 13:10*
WD : 259 Deg
WS : 12 m/s
T : 28.0 °C
RH : 89 %
DT : 25.0 °C
P : 29.2 hPa
a : 0.0
p : 0.0 hPa
QFE : 29.3 hPa
QFF : 1 hPa
QNH : 0.2 hPa
PA : 0.0 m
DA : 0.0 m
a =Next
The Main screen shows the key values of the standard measurements
and calculations.
Table 3 Main Screen Information
Screen text Measurement Unit SI (US) Note
MAWS1 Station name
Main Screen name
13:10 Current time
* The handheld
terminal receives
data when the
asterisk is seen.
WD Wind direction Deg
WS Wind speed m/s (kt)
T Air temperature
°C (°F)
RH Relative humidity %
DT Dew point
°C (°F)
P Barometric pressure hPa (inHg)
a Pressure tendency code 0 ... 8 Available after 3
hours
p Pressure trend (3 h) hPa (inHg) Available after 3
hours
QFE Field pressure hPa (inHg)
QFF Sea-level pressure hPa (inHg)
QNH Altimeter setting hPa (inHg) Available after 5
minutes
PA Pressure altitude m (ft)
DA Density altitude m (ft)