User`s guide

User's Guide ______________________________________________________________________
52 __________________________________________________________________ M210455EN-B
Status
Press on Alarms screen to get to the Status screen:
MAWS1 Status 13:10
Int. Batt : 6.8 V
Int. Temp : 25 °C
QMP202MP : 11.3 V
AC (mains): On
Al. Limit : 10.8 V
CTRL 1 Reset
CTRL 2 Sleep
CTRL 3 Restart
a ↓↑=Next/Prev
The Status screen shows voltage information and internal temperature
of the TACMET MAWS logger.
Table 11 Status Screen Information
Screen label Explanation Limit value
Int. Batt Internal battery voltage of MAWS (V) 5.5 ... 7.6 V
Int. temp
Internal temperature of MAWS
(°C or °F) -40 ... +80 °C
-40 ... +176 °F
QMP202MP Battery voltage of QMP202MP (V) 10 ... 16 V
AC (mains) AC power to MAWS (ON/OFF)
Al Limit MAWS sends an alarm to the handheld
terminal when the QMP202MP voltage
drops below the set limit.
CTRL 1 Press CTRL+1 to reset MAWS
CTRL 2 Press CTRL+2 to put MAWS into sleep
mode. MAWS wakes up when you connect
the handheld terminal and turn it on.
CTRL 3 Press CTRL+3 to restart MAWS from sleep
mode.