User`s guide

User's Guide ______________________________________________________________________
54 __________________________________________________________________ M210455EN-B
NOTE
If you are not able to get the input field, it means that there is a
communication problem between TACMET MAWS and the
handheld terminal. See section troubleshooting the Handheld
Terminal on page 114.
Table 12 Station Dependent Settings
Screen label Setting
Name Select a desired station name (max. 8 characters). The
station name is a static parameter and will remain after
power off.
Time Time and date. Set the time according to the example. To
set only the time, type for example 13 15 00 (hh mm ss).
Timez Time zone sets the time difference from UTC. For example,
enter -5 in the eastern USA (New York, for example). For
details, see Figure 30 on page 55.
Alt Station altitude from sea level. Use the same unit as
selected in the Units-field.
Pslev Pressure sensor altitude from the ground (station level).
Use the same unit as selected in the Units-field.
WindC Should always be set to 0 in mast installations.
Rf-HT Select the desired radio channel (0 ... 15) for the radio
connected to the Hand Terminal connector on the upper
base of the logger tube. This may take up to 1 min. Set
channel to -1 to pause radio transmission.
Rf-PC Select the desired radio channel (0 ... 15) for the radio
connected to the PC connector on the lower base of the
logger tube. This may take up to 1 min. Set channel to -1 to
pause radio transmission.
Sys.T System Type: 0 = deployable, 1 = mast installation
Enh Enhancement sensors included in configuration. 0 = Not
included, 1 = Included. Set to 1 in mast installations.
Units Display unit: 0 = SI units, 1 = US units. Display unit will
change when a value is logged the next time.