User`s guide

USER'S GUIDE____________________________________________________________________
102 _________________________________________________________________ M211095EN-C
MEAS — Start Measurement
This command starts wind measurement based on the user-configurable
averaging time. WMT700 does not send the data message automatically.
Use the polling command to fetch the measurement data in the required
format.
$aMEAS<CR><LF>
Where
$ = Fixed text.
a = WMT700 address. If the value is 0, it refers to any
WMT700 address.
OPEN — Enter Configuration Mode
This command switches the serial port to configuration mode.
$aOPEN<CR><LF>
Where
$ = Fixed text.
a = WMT700 address. If the value is 0, it refers to any
WMT700 address.